Removing Rangefinder Assembly
(Figures 4-11 through 4-13)
On the model 600SE, slide the bar marked 127 150 away from the eyepiece. Unhook spring.
Remove anchor screw.
Figure 4-11. Unhook spring, remove anchor screw
Place camera in vertical position. Remove two screws, shown in Figure 4-12.
Figure 4-12. Removing screws securing viewfinder assembly to camera body
Spring
Anchor Screw
Retaining Screw
Retaining Screw
Anchor Screw