53
Connecting to the CL-GigE and Configuring General Settings Using eBUS Player
3.
Under
TransportLayerControl\GigEVision
, set the
GevCurrentIPConfigurationPersistentIP
feature to
True
.
4.
Set the
GevPersistentIPAddress
feature to an IP address that is compatible with your computer’s
NIC.
5.
Set the
GevPersistentSubnetMask
feature to a compatible subnet mask address.
6.
Optionally, enter a compatible default gateway in the
GevPersistentDefaultGateway
field.
7.
Close the
Device Control
dialog box.
8.
Disconnect the camera from the CL-GigE, power cycle the CL-GigE, and reconnect the camera.
To automatically configure an IP address
1.
Start eBUS Player and connect to the CL-GigE.
For more information, see
“To start eBUS Player and connect to the CL-GigE”
2.
Under
Parameters and Controls
, click
Device control
.
3.
Under
TransportLayerControl\GigEVision
, set the
GevCurrentIPConfigurationPersistentIP
feature to
False
.
4.
Set the
GevCurrentIPConfigurationLLA
and/or
GevCurrentIPConfigurationDHCP
values to
True
, depending on the type of automatic addressing you require.
5.
Close the
Device Control
dialog box.
6.
Disconnect the camera from the CL-GigE, power cycle the CL-GigE, and reconnect the camera.