Technical details
Operating Manual PSEN sg2c-5CCLLE
1004172-EN-02
| 45
10
Technical details
General
Certifications
CE, FCC, TÜV, cULus Listed
Sensor's mode of operation
Transponder
Coding level in accordance with EN ISO 14119
Low
Design in accordance with EN ISO 14119
4
Pilz coding type
Coded
Transponder
Frequency band
122 kHz - 128 kHz
Max. transmitter output
15 mW
Electrical data
Supply voltage
Voltage
24 V
Kind
DC
Voltage tolerance
-15 %/+10 %
Output of external power supply (DC)
2 W
Max. inrush current at UB
5 A
Max. switching frequency
1 Hz
Magnet. supply voltage
24 V
Max. solenoid current t <150 ms
1,5 A
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts
40 nF
PNOZmulti, PNOZelog, PSS
70 nF
Max. inrush current impulse
Current pulse, A1
5 A
Pulse duration, A1
0,0002 ms
Max. unit fuse protection in accordance with UL
3 A
Inputs
Number
2
Input voltage in accordance with EN 61131-2 Type 2
24 V DC
Current per input
5 mA
E-STOP
Number of N/C contacts
2
E-STOP release type
Turn release
Utilisation category
In accordance with the standard
EN 60947-5-1
AC15 at
24 V
Current
1,5 A
DC13 at
24 V
Current
1,5 A
Mechanical life
6050 cycles
Signal output
Output voltage
24 V
Max. current
100 mA