Technical details
Operating Manual PSEN sg2c-5CCLLE
1004172-EN-02
| 47
Environmental data
Vibration
In accordance with the standard
EN 60068-2-6
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
In accordance with the standard
EN 60068-2-27
Acceleration
30g
Duration
11 ms
Airgap creepage
Overvoltage category
III
Pollution degree
3
Rated insulation voltage
30 V
Rated impulse withstand voltage
1 kV
Protection type
Housing
IP54
In accordance with UL
type 1
Mechanical data
Escape release available
yes
Mechanical life
200,000 cycles
Max. holding force Fzh in closing direction
1000 N
Max. holding force Fzh in pan direction
2000 N
Max. vertical offset
+/-2,5 mm
Max. lateral offset
+/-3,0 mm
Max. angular offset
+/-1,5 deg
Max. retract speed of actuator
0,5 m/s
Actuator 1
PSEN sg2 actuator
Operating distances
Typ. Hysteresis
0,1 mm
Assured operating distance Sao
2 mm
Min. operating distance Somin
3 mm
Typical operating distance So
3 mm
Assured release distance Sar
4 mm
Change of operating distance with temperature
changes
+-0,01mm/°C
Connection type
Spring-loaded terminal, plug-in
Cable
LiYY 24 x 0.5 mm2
Material
Top
Plastic
Actuator
Stainless steel
Dimensions
Height
555 mm
Width
200 mm
Depth
108 mm