Maintenance
Operating Manual PSEN sg2c-5CCLLE
1004172-EN-02
| 40
8
Maintenance
Maintenance of the escape release:
}
Check the correct functionality of the escape release at least every once per month.
When dust, humidity, chemical or dirt exposure is high we recommend that you keep to
shorter intervals.
Please note that the cover of the escape release must also be checked for damage and
then re-installed.
}
Clean the escape release and the bolt tongue and test their mobility.
}
If there are signs of wear on the safety switch or the mechanics are sluggish, check that
the handle unit with actuator is correctly aligned with the switch. If necessary, re-adjust
the handle unit with actuator.
Otherwise no maintenance work needs to be performed on the interlocking and guard lock-
ing system PSEN sg2c-5CCLLE. Please return any faulty devices to Pilz.