User Manual
E727T0005, valid for E-727
BRO, 2019-06-28
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 199 / 240
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
Parameter
ID (hexa-
decimal)
Data
Type
Command
Level for
Write
Access
Item Type
Parameter
Name
Description
0x0f000100
CHAR
1
Input signal
channel
Stage Type
ID-chip
0x0f000200
CHAR
1
Input signal
channel
Stage Serial
Number
ID-chip
0x0f000300
CHAR
1
Input signal
channel
Stage assembly
Date
ID-chip
0x0f000700
INT
3
Input signal
channel
ID-Chip Data
Valid
ID-chip present? Valid data read?
0x10000500 INT
1
Axis
FastIF Axis Input
Usage
Determines the usage of the data
received from the host via data
segment 1 of the SPI interface.
For details, see “Configuring the
Usage of Received Data” (p. 145).
0x10000501 INT
1
System
FastIF Data Type Selects the data type for the data
sent via data segment 1 of the SPI
interface.
When the 32 bit floating point
data type is selected then the
data can be read and written
directly in axis units. In this case
no scaling is necessary.
When any of the integer data
types is selected then scaling is
necessary. In this case the lower
and upper limit parameters must
also be set (Fast IF Data Low Limit
0x10000502, Fast IF Data High
Limit 0x010000503).
0 = FLOAT 32 bit
1 = UINT 16 bit
2 = UINT 24 bit
3 = UINT 32 bit
4 = SIGNED 16 bit
5 = SIGNED 24 bit
6 = SIGNED 32 bit
0x10000502 FLOAT 1
Axis
FastIF Data Low
Limit
Lower limit for the data sent via
data segment 1 of the SPI
interface.
Must be set when any integer
data type is selected (Fast IF Data
Type, 0x10000501) so that the
scaling can be calculated
internally.