User Manual
E727T0005, valid for E-727
BRO, 2019-06-28
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 196 / 240
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
Parameter
ID (hexa-
decimal)
Data
Type
Command
Level for
Write
Access
Item Type
Parameter
Name
Description
0x0b000007 FLOAT 1
Output
signal
channel
Min Output
Voltage of
Amplifier
Settings valid when used as
output voltage for a piezo
actuator in the stage (output on
the socket for piezo stages).
Limited by Soft Voltage Low Limit
(ID 0x0c000000) and Soft Voltage
High Limit (ID 0x0c000001).
0x0b000008 FLOAT 1
Output
signal
channel
Max Output
Voltage of
Amplifier
0x0b000009 FLOAT 2
Output
signal
channel
Voltage of
Amplifier with
zero to Dac
0x0b00000a FLOAT 1
Output
signal
channel
Voltage Offset
of Amplifier
0x0b000500 INT
1
Output
signal
channel
Output
Numerical
Format
7 = raw format (used for
driver/DAC issues)
0x0b000800 INT
1
Output
signal
channel
Input Index To
Feed Back
Not relevant for E-727
0x0b000a00 FLOAT 2
Output
signal
channel
Min Output
Voltage of 2nd
Output
Settings valid when used as
control signal for an external
amplifier (output on pin 8 of the
Analog I/O
socket).
Only present with E-727 models
equipped with an
Analog I/O
socket (E-727.xxxA, .xxxAx).
0x0b000a01 FLOAT 2
Output
signal
channel
Max Output
Voltage of 2nd
Output
0x0b000a02 FLOAT 2
Output
signal
channel
Voltage of 2nd
Output with
zero to Dac
0x0c000000
FLOAT 1
Output
signal
channel
Soft Voltage
Low Limit
ID-chip
Limits the output voltage for a
piezo actuator in the stage
(output on the socket for piezo
stages).
0x0c000001
FLOAT 1
Output
signal
channel
Soft Voltage
High Limit
0x0d000000 CHAR
2
System
Device S/N
0x0d000100 CHAR
2
System
Hardware S/N
0x0d000200 CHAR
2
System
Hardware Name
0x0d000300 INT
3
System
Fieldbus
Product Code
Identification of the E-727 in the
EtherCat network
0x0e000100 FLOAT 2
System
Sensor Sampling
Time
[s]