7.1.3
Trigger
This tab contains trigger and strobe settings.
Figure 7.4: MV1-D1312-160 trigger panel
Trigger
Trigger Source:
Free running:
The camera continuously delivers images with a certain configurable frame rate.
Interface Trigger:
The Trigger signal is applied to the camera by the CameraLink frame grabber
or the USB interface respectively.
I/O Trigger:
The trigger signal is applied directly to the camera on the power supply connector.
Exposure time defined by:
Camera:
The exposure time is defined by the property
ExposureTime
.
Trigger Pulse Width:
The exposure time is defined by the pulse width of the trigger signal
(level-controlled exposure).
This property disables LinLog, Burst trigger and simultaneous readout mode.
Exposure time defined by "Trigger Pulse Width" is also known as Level controlled
trigger.
Further trigger settings:
7.1 MV1-D1312(I)-40, MV1-D1312(I)-80, MV1-D1312(I)-160 and MV1-D1312-240
91
Summary of Contents for CameraLink MV1-D1312 series
Page 1: ...User Manual MV1 D1312 I CameraLink Series CMOS Area Scan Camera MAN041 09 2010 V2 5...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started CameraLink 12...
Page 24: ...3 Product Specification 22...
Page 72: ...4 Functionality Figure 4 56 Unsharp Mask Examples 70...
Page 110: ...8 Mechanical and Optical Considerations 108...
Page 112: ...9 Warranty 110...
Page 114: ...10 References 112...
Page 118: ...A Pinouts 116...