![Photon Focus CameraLink MV1-D1312 series User Manual Download Page 55](http://html1.mh-extra.com/html/photon-focus/cameralink-mv1-d1312-series/cameralink-mv1-d1312-series_user-manual_1553524055.webp)
the timing in the section Fig. 4.35. This trigger pulse then starts after a user configurable burst
trigger delay time t
burst
−
trigger
−
delay
the internal burst engine, which generates n internal
triggers for the shutter- and the strobe-control. A user configurable value defines the time
t
burst
−
period
−
time
between two acquisitions.
MV1-D1312(I)-40
MV1-D1312(I)-40
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
45 ns
60 ns
t
jitter
0
100 ns
t
trigger
−
delay
0
1.68 s
t
burst
−
trigger
−
delay
0
1.68 s
t
burst
−
period
−
time
depends on camera settings
1.68 s
t
trigger
−
offset
(non burst mode)
400 ns
400 ns
t
trigger
−
offset
(burst mode)
500 ns
500 ns
t
exposure
10
µ
s
1.68 s
t
strobe
−
delay
0
1.68 s
t
strobe
−
offset
(non burst mode)
400 ns
400 ns
t
strobe
−
offset
(burst mode)
500 ns
500 ns
t
strobe
−
duration
200 ns
1.68 s
t
d
−
iso
−
output
45 ns
60 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 4.10: Summary of timing parameters relevant in the external trigger mode using camera (MV1-
D1312(I)-40)
4.4.6
Software Trigger
The software trigger enables to emulate an external trigger pulse by the camera software
through the serial data interface. It works with both burst mode enabled and disabled. As
soon as it is performed via the camera software, it will start the image acquisition(s),
depending on the usage of the burst mode and the burst configuration. The trigger mode
must be set to
Interface Trigger
or
I/O Trigger
.
4.4.7
Strobe Output
The strobe output is an opto-isolated output located on the power supply connector that can
be used to trigger a strobe. The strobe output can be used both in free-running and in trigger
mode. There is a programmable delay available to adjust the strobe pulse to your application.
The strobe output needs a separate power supply. Please see Section Section
5.1.3 and Figure Fig. 4.32 and Fig. 4.33 for more information.
.
4.4 Trigger and Strobe
53
Summary of Contents for CameraLink MV1-D1312 series
Page 1: ...User Manual MV1 D1312 I CameraLink Series CMOS Area Scan Camera MAN041 09 2010 V2 5...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started CameraLink 12...
Page 24: ...3 Product Specification 22...
Page 72: ...4 Functionality Figure 4 56 Unsharp Mask Examples 70...
Page 110: ...8 Mechanical and Optical Considerations 108...
Page 112: ...9 Warranty 110...
Page 114: ...10 References 112...
Page 118: ...A Pinouts 116...