5 Hardware Interface
5.1.3
Trigger and Strobe Signals
The power connector contains an external trigger input and a strobe output.
The trigger input is equipped with a constant current diode which limits the
current of the optocoupler over a wide range of voltages. Trigger signals can
thus directly get connected with the input pin and there is no need for a current
limiting resistor, that depends with its value on the input voltage. The input
voltage to the
TRIGGER
pin must not 15V DC, to avoid damage to the
internal ESD protection and the optocoupler!
In order to use the strobe output, the internal optocoupler must be powered with 5 .. 15 V DC.
The
STROBE
signal is an open-collector output, therefore, the user must connect a pull-up
resistor (see Table 5.1) to
STROBE_VDD
(5 .. 15 V DC) as shown in Fig. 5.2. This resistor should be
located directly at the signal receiver.
Figure 5.2: Circuit for the trigger input signals
The maximum sink current of the
STROBE
pin is 8 mA.
Do not connect inductive
or capacitive loads
, such loads may result in damage of the optocoupler! If the
application requires this, please use voltage suppressor diodes in parallel with
this components to protect the optocoupler.
80
Summary of Contents for CameraLink MV1-D1312 series
Page 1: ...User Manual MV1 D1312 I CameraLink Series CMOS Area Scan Camera MAN041 09 2010 V2 5...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started CameraLink 12...
Page 24: ...3 Product Specification 22...
Page 72: ...4 Functionality Figure 4 56 Unsharp Mask Examples 70...
Page 110: ...8 Mechanical and Optical Considerations 108...
Page 112: ...9 Warranty 110...
Page 114: ...10 References 112...
Page 118: ...A Pinouts 116...