MV1-D1312(I)-240
MV1-D1312(I)-240
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
45 ns
60 ns
t
jitter
0
16.7 ns
t
trigger
−
delay
0
0.28 s
t
burst
−
trigger
−
delay
0
0.28 s
t
burst
−
period
−
time
depends on camera settings
0.28 s
t
trigger
−
offset
(non burst mode)
66.7 ns
66.7 ns
t
trigger
−
offset
(burst mode)
83.3 ns
83.3 ns
t
exposure
10
µ
s
0.28 s
t
strobe
−
delay
0
0.28 s
t
strobe
−
offset
(non burst mode)
66.7 ns
66.7 ns
t
strobe
−
offset
(burst mode)
83.3 ns
83.3 ns
t
strobe
−
duration
200 ns
0.28 s
t
d
−
iso
−
output
45 ns
60 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 4.13: Summary of timing parameters relevant in the external trigger mode using camera (MV1-
D1312(I)-240)