MV1-D1312(I)-240
Pixel Clock per Tap
80 MHz
Number of Taps
3
Greyscale resolution
8 bit
Line pause
12 clock cycles
CC1
EXSYNC
CC2
not used
CC3
not used
CC4
not used
Table 3.8: Summary of parameters needed for frame grabber configuration
Bit
Tap 0
Tap 0
Tap 0
8 Bit
10 Bit
12 Bit
0 (LSB)
A0
A0
A0
1
A1
A1
A1
2
A2
A2
A2
3
A3
A3
A3
4
A4
A4
A4
5
A5
A5
A5
6
A6
A6
A6
7 (MSB of 8 Bit)
A7
A7
A7
8
-
B0
B0
9 (MSB of 10 Bit)
-
B1
B1
10
-
-
B2
11 (MSB of 12 Bit)
-
-
B3
Table 3.9: CameraLink
®