7 Graphical User Interface (GUI)
Missed Trigger:
This is a counter for trigger pulses that were blocked because the trigger pulse
was received during image exposure or readout. In free-running mode it counts all pulses
received from interface trigger or from I/O trigger interface.
Missed Burst Trigger:
This is a counter for burst trigger pulses that were blocked because the
burst trigger pulse was received during the last burst is not yet finished.
To update the value of the information properties, click on the Update-Button; to reset the
properties, click on the Reset-Button.
Status Line
Enable Status Line:
The status line replaces the last line of an image with image information,
please refer the manual for additional information.
Temperature
Imager PCB [deg C
:] The temperature of the imager PCB.
Imager [deg C
:] The temperature of the imager device.
ADC PCB [deg C
:] The temperature of the Analog-Digital-Converter PCB.
Update:
Press this button to update all temperature values.