a
y = f ( x )
x
x
m a x
x
0
x
1
y
m a x
b
c
d
Figure 4.44: Commonly used LUT transfer curves
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gain: y = (255/1023)
⋅
a
⋅
x
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
a = 1.0
a = 2.0
a = 3.0
a = 4.0
Figure 4.45: Applying a linear gain with clamping to an image
4.8 Grey Level Transformation (LUT)
63
Summary of Contents for CameraLink MV1-D1312 series
Page 1: ...User Manual MV1 D1312 I CameraLink Series CMOS Area Scan Camera MAN041 09 2010 V2 5...