Startup and configuration
7900_en_01
PHOENIX CONTACT
37
2.5
SSC script
Configuration via SSC script is the right option if a number of EPAs must be identically or
similarly configured. A script can be executed on all current Windows PCs without any
further installation. It allows for configurations that can be reproduced quickly and without
errors.
SSC is based on the Windows Scripting Host (WSH) that has been an integral part of all
current Windows versions since Windows 98.
For a detailed description containing examples, please refer to (SimpleScriptConfiguration
download.phoenixcontact.com
.
Load Configuration
Load and execute configuration commands from a file.
In combination with “Read all settings” the entire configura-
tion can be restored.
Reload Settings
Read again all indications of the WBM fields from the EPA.
Write all
Transmit all the current settings to the EPA.
Reboot
Trigger reboot of EPA.
AT commands (only displayed in “Advanced View”)
AT commands
Send
Enter AT commands in the text box and transmit to EPA via
“Send” button.
AT response
(Text window)
Shows the AT commands and their responses.
Firmware update from TFTP
Server IP Address
Enter IP address of the TFTP server that provides the firm-
ware file.
File name
Enter name of the firmware file.
Update
Start firmware update.
Ensure that TFTP transmission is not blocked by a firewall.