FL BT EPA
50
PHOENIX CONTACT
7900_en_01
Operating mode
PANU, NAP
Configuration
Via web-based management, AT commands, script, MODE button
Security
128-bit data encryption, authentication, PIN, non-discoverable
Interfaces [...]
Mechanical tests
Shock test according to IEC 60068-2-27
Operation: 25g, 11 ms period,
half-sine shock pulse
Storage/transport: 50g, 11 ms period,
half-sine shock pulse
Vibration resistance according to IEC 60068-2-6
Operation/storage/transport: 5g, 10 ... 150 Hz, Criterion 3
Free fall according to IEC 60068-2-32
1 m
Approvals
FCC/CFR 47 Part 15, ETS 300 328
Conformance With EMC Directives
Noise emission according to EN 55022
Class B
Radio interference field strengths according to EN 55022
Class A
Electrostatic discharge (ESD) according to EN 61000-4-2
Contact discharge: ±4 kV
Air discharge: ±8 kV
Electromagnetic fields according to IEC 61000-4-3
10 V/m; Criterion A
Conducted interference
according to IEC 61000-4-6
10 V
RMS
; Criterion A
Fast transients (burst)
according to IEC 61000-4-4
Data lines: 1 kV; Criterion B
Power supply lines: 0.5 kV; Criterion B
Surge voltages according to IEC 61000-4-5
Data lines: ±1 kV asymmetrical; Criterion B
Power supply lines: ±0.5 kV symmetrical/asymmetrical; Criterion B
Differences between this version and previous versions
Rev. 00: First version
Rev. 01: Multiport devices integrated