“Ports, Port Mirroring” menu
Activation/deactivation and setting of port mirroring. Port mirroring is used to passively read
input or output data that is being transmitted via a selected port. To do this, a measuring in-
strument (PC) is connected to the destination port, which records the data, yet must not it-
self be activated.
Figure 4-26
“Port Mirroring” web page
“Diagnostics, Alarm Contact” Menu
Here, you can set whether and for which events the signal contact (alarm contact) is used.
Figure 4-27
“Alarm Contact” web page
WBM prevents the same ports from being set, i.e., the source port and destination port
must differ.
The port capacity is calculated according to the set transmission parameters. Example: A
source port is operated at 100 Mbps and reaches a capacity of 5%. The destination port
is operated at 10 Mbps. Therefore, with the same volume of data, the destination port
reaches a capacity of 50%.