Technical data and ordering data
8089_en_03
PHOENIX CONTACT
167
11 Technical data and ordering data
11.1 Technical data
General data
Function
Smart Managed Narrow Switch, Ethernet/Fast Ethernet switch; conforms to
standard IEEE 802.3/802.3u/802.3ab
Switch principle
Store and forward
Address table
4000 MAC addresses
SNMP
Version 2c
Transmission capacity per port
64-byte packet size, half duplex
At 10 Mbps:
14880 pps (packets per second)
At 100 Mbps:
148800 pps
Supported MIBs
MIB II and private SNMP objects from Phoenix Contact
Housing dimensions (width x height x depth) in mm
56 x 133 x 130 (depth from top edge of DIN rail)
56 x 133 x 175 (depth from top edge of DIN rail)
with FL MEM PLUG (accessories)
Permissible operating temperature
0°C to 55°C
Permissible storage temperature
-40°C to +85°C
Degree of protection
IP20, IEC 60529
Protection class
Class 3 VDE 0106; IEC 60536
Humidity
Operation
5% ... 95%, non-condensing
Storage
5% ... 95%, non-condensing
Air pressure
Operation
86 kPa to 108 kPa, 1500 m above sea level
Storage
66 kPa to 108 kPa, 3500 m above sea level
Ambient compatibility
Free from substances that would hinder coating with paint or varnish accord-
ing to VW specification
Mounting position
Perpendicular to a standard DIN rail
Connection to protective earth ground
By snapping it onto a grounded DIN rail
Weight
650 g, typical
Supply voltage (US1/US2 redundant)
Connection
Via COMBICON; maximum conductor cross section = 2.5 mm
2
Nominal value
24 V DC
Permissible voltage range
18.0 V DC to 32.0 V DC
Permissible ripple (within the permissible voltage range)
3.6 V
PP
Test voltage
500 V DC for 1 minute
Current consumption at US at 24 V DC, maximum
0.6 5A
Maximum power consumption
14.5 W
Interfaces on the SMN
Number of Ethernet ports
8
RS-232 communication interface
Connection format
Mini-DIN socket
Summary of Contents for 2700290
Page 1: ...User manual Smart Managed Narrow Switch Order No ...
Page 8: ...FL SWITCH SMN 6 PHOENIX CONTACT 8089_en_03 ...
Page 24: ...Smart Managed Compact Switch 24 PHOENIX CONTACT 8089_en_03 ...
Page 42: ...Smart Managed Compact Switch 42 PHOENIX CONTACT 8089_en_03 Figure 4 24 Diagnostics web page ...
Page 108: ...Smart Managed Compact Switch 132 PHOENIX CONTACT 8089_en_03 ...
Page 114: ...Smart Managed Compact Switch 138 PHOENIX CONTACT 8089_en_03 ...
Page 148: ...Smart Managed Compact Switch 172 PHOENIX CONTACT 8089_en_03 ...
Page 150: ...Smart Managed Compact Switch 178 PHOENIX CONTACT 8089_en_03 ...