Technical data and ordering data
8089_en_03
PHOENIX CONTACT
169
Transmission power
Minimum
-15 dBm 9/125 µm
Receiver sensitivity
Minimum
-31.0 dBm
Ethernet interfaces [...]
Mechanical tests
Shock testing according to IEC 60068-2-27
Operation:25g,
Half-sine shock pulse
Storage/transport: 50g,
Half-sine shock pulse
Vibration resistance according to IEC 60068-2-6
Operation/storage/transport: 5g, 10 Hz ... 150 Hz
Free fall according to IEC 60068-2-32
1 m
Conformance with EMC directives
Developed according to IEC 61000-6-2
Noise emission according to EN 55022: 1998
+ A1: 2000 + A2: 2003 (interference voltage)
Class B (residential)
Noise emission according to EN55011: 1998
+ A1: 1999 + A2: 2002 (electromagnetic interference)
Class B (residential)
Noise immunity according to EN 61000-4-2 (IEC1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 3, criterion B
Test intensity 2, criterion B
Noise immunity according to EN 61000-4-3 (IEC 1000-4-3)
(electromagnetic fields)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-4 (IEC 1000-4-4) (burst)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 3, criterion B
Noise immunity according to EN 61000-4-5 (IEC 1000-4-5) (surge)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B
Test intensity 1, criterion B
Noise immunity according to EN 61000-4-6 (IEC 1000-4-6) (conducted)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Additional certification
RoHS
EEE 2002/95/EC - WEEE 2002/96/EC
Differences between this version and previous versions
Rev. 00: First version
Rev. 01: Integration of FL SWITCH SMN 8TX-PN
Rev. 02: New firmware
Rev. 03: New devices added
Summary of Contents for 2700290
Page 1: ...User manual Smart Managed Narrow Switch Order No ...
Page 8: ...FL SWITCH SMN 6 PHOENIX CONTACT 8089_en_03 ...
Page 24: ...Smart Managed Compact Switch 24 PHOENIX CONTACT 8089_en_03 ...
Page 42: ...Smart Managed Compact Switch 42 PHOENIX CONTACT 8089_en_03 Figure 4 24 Diagnostics web page ...
Page 108: ...Smart Managed Compact Switch 132 PHOENIX CONTACT 8089_en_03 ...
Page 114: ...Smart Managed Compact Switch 138 PHOENIX CONTACT 8089_en_03 ...
Page 148: ...Smart Managed Compact Switch 172 PHOENIX CONTACT 8089_en_03 ...
Page 150: ...Smart Managed Compact Switch 178 PHOENIX CONTACT 8089_en_03 ...