Mounting and installation
8089_en_03
PHOENIX CONTACT
17
2.2.2
Signal contact
The switch has a floating signal contact. An error is indicated when the contact is opened.
Figure 2-5
Basic circuit diagram for the signal contact
The indicated error states are configured in web-based management or via SNMP. For a list
of error states that can be configured, please refer to Section ““Diagnostics, Alarm Contact”
Menu” on page 44.
2.2.3
Assignment of the RJ45 Ethernet connectors
In the event of a non-redundant voltage supply, the switch indicates the voltage supply
failure by opening the signal contact. This error message can be prevented by connecting
the supply voltage to both terminal blocks in parallel, as shown in Figure 2-3, or by deac-
tivating redundant power supply monitoring in web-based management or via SNMP.
Table 2-1
Pin assignment of RJ45 connectors
Pin number
10Base-T / 10 Mbps
100Base-T / 100 Mbps
1
TD+ (transmit)
TD+ (transmit)
2
TD- (transmit)
TD- (transmit)
3
RD+ (receive)
RD+ (receive)
4
-
-
5
-
-
6
RD- (receive)
RD- (receive)
7
-
-
8
-
-
R1
R2
67842015
Summary of Contents for 2700290
Page 1: ...User manual Smart Managed Narrow Switch Order No ...
Page 8: ...FL SWITCH SMN 6 PHOENIX CONTACT 8089_en_03 ...
Page 24: ...Smart Managed Compact Switch 24 PHOENIX CONTACT 8089_en_03 ...
Page 42: ...Smart Managed Compact Switch 42 PHOENIX CONTACT 8089_en_03 Figure 4 24 Diagnostics web page ...
Page 108: ...Smart Managed Compact Switch 132 PHOENIX CONTACT 8089_en_03 ...
Page 114: ...Smart Managed Compact Switch 138 PHOENIX CONTACT 8089_en_03 ...
Page 148: ...Smart Managed Compact Switch 172 PHOENIX CONTACT 8089_en_03 ...
Page 150: ...Smart Managed Compact Switch 178 PHOENIX CONTACT 8089_en_03 ...