M
AINTENANCE
:
2
0 2 . 9 6 8 5 . 0 0 1 0 A
21-May-2009
53
Low Voltage Supply (LVS) Temperature PCB
Replacement (VL500/VL500D/VL500A Only)
Parts:
24.9685.0740
1 EA
TEMPERATURE BOARD, LVS
Tools:
•
#2 Phillips Screwdriver
WARNING:
Remove power from luminaire before performing maintenance.
WARNING:
With power applied, LIVE AC is present at heatsink. Do not touch when unit
is powered.
To remove and replace LVS temperature PCB:
Step
1. Remove power from luminaire.
Step
2. Remove LVS by following procedure,
“Low Voltage Supply (LVS) Replacement
(VL500/VL500D/VL500A Only)” on page 52
.
Figure 26: LVS Temperature PCB Replacement (VL500/VL500D/VL500A Only)
Step
3. Disconnect the following wiring connections on PCB:
a.
2-position connector (LVS Fan)
b. 4-position connector (LVS Fan from MCB)
Step
4. As shown in
Figure 26
, remove one 1/4" hex standoff.
Step
5. Remove LVS Temperature PCB.
Step
6. Replace by performing steps 2 through 5 in reverse order.
LVS Temperature PCB
1/4" Hex Standoff
Some components not shown for clarity.
NOTE:
Yoke Arm
Summary of Contents for Vari-Lite VL500
Page 1: ......
Page 13: ...SAFETY NOTICE JAPANESE 02 9685 0010 A 21 May 2009 xiii ...
Page 14: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL xiv 21 May 2009 02 9685 0010 A ...
Page 34: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 16 21 May 2009 02 9685 0010 A Notes ...
Page 118: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 100 21 May 2009 02 9685 0010 A Notes ...
Page 168: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 150 21 May 2009 02 9685 0010 A Notes ...
Page 212: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 194 21 May 2009 02 9685 0010 A Notes ...
Page 218: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 200 21 May 2009 02 9685 0010 A Notes ...
Page 219: ......