M
AINTENANCE
:
2
0 2 . 9 6 8 5 . 0 0 1 0 A
21-May-2009
43
Linear Actuator Motor Replacement (Amber/Dif-
fuser [or Dimmer] Bulkhead)
Parts:
44.9685.0230
2 EA
MOTOR, LINEAR, 0.002"/STEP
Tools:
•
#1 Phillips Screwdriver
•
#2 Phillips Screwdriver
•
#2 Slotted Screwdriver
WARNING:
Remove power from luminaire before performing maintenance.
To remove and replace linear actuator motor assembly:
Step
1. Remove power from luminaire.
Step
2. Set the luminaire head horizontally.
Step
3. Engage tilt service lock to secure luminaire head in horizontal position to access
heatsink latch.
Figure 17: Amber/Diffuser (or Dimmer) Bulkhead - Linear Actuator Motors
Step
4. Remove top head cover.
Note:
Linear actuator motors should be seen with cover removed. If not, flip head over.
Magenta/Blue Assembly*
Amber/Diffuser Assembly
(Incandescent Models)
Amber/Dimmer Assembly
(Arc Models)
or
Some components not shown for clarity.
NOTE:
Linear Actuator
*See separate procedure for
linear motor replacement for
these assemblies.
Heatsink Assembly
Front Ring
Motor Assembly
Top Cover
Summary of Contents for Vari-Lite VL500
Page 1: ......
Page 13: ...SAFETY NOTICE JAPANESE 02 9685 0010 A 21 May 2009 xiii ...
Page 14: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL xiv 21 May 2009 02 9685 0010 A ...
Page 34: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 16 21 May 2009 02 9685 0010 A Notes ...
Page 118: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 100 21 May 2009 02 9685 0010 A Notes ...
Page 168: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 150 21 May 2009 02 9685 0010 A Notes ...
Page 212: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 194 21 May 2009 02 9685 0010 A Notes ...
Page 218: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 200 21 May 2009 02 9685 0010 A Notes ...
Page 219: ......