11
113
11
Monitoring Twin FHRs
You can monitor twin FHRs externally using two ultrasound transducers. It is not possible to monitor
twins externally using cordless ultrasound transducers.
FM30/50
Additionally, you can monitor twin FHRs throughout labor and delivery after rupture of the
membranes by monitoring one twin externally using ultrasound and the other internally using DECG.
Refer to the appropriate preceding chapters for contra-indications and other information about the
measurement methods you have chosen.
FHR detection by the monitor may not always indicate that the fetuses are alive. Confirm fetal life
before monitoring, and continue to confirm that the fetuses are the signal source for the recorded
heart rate.
Important Considerations
When monitoring:
•
Make sure that you are recording two different heart rates. The cross-channel verification feature
alerts you if the two heart rates coincide (that is, if both transducers are recording the same FHR).
If this happens, check the trace and if necessary, reposition an ultrasound transducer to detect the
second FHR correctly.
•
Fetal heart rate measurements are labeled in the
order
in which you plug in the transducers for
those measurements. It does not matter which fetal sensor socket you use, as the monitor allocates
a channel automatically. For instance, the first transducer you connect is automatically allocated a
channel, and the measurement is labeled
FHR1
, the second is labeled
FHR2
, and so on.
If you need to disconnect the transducers measuring the FHR temporarily, with the intention to
continue monitoring after the temporary break (for example, if the mother needs to go to the
bathroom), it is important that you reconnect the transducers in the same order as you originally
connected them to make sure the measurement labels remain consistent.
•
The blue transducer Finder LED lets you identify at a glance which transducer is monitoring
which heart rate channel.
•
The fetal sensor socket to which a transducer is connected is identified by the transducer position
indicator in the blue setup menu header:
for FM20/30;
Summary of Contents for Avalon FM20
Page 2: ......
Page 8: ...8 ...
Page 56: ...3 Basic Operation 56 ...
Page 72: ...5 Alarms 72 ...
Page 82: ...6 Patient Alarms and INOPs 82 ...
Page 86: ...7 Admitting and Discharging 86 ...
Page 90: ...8 Non Stress Test Timer 90 ...
Page 120: ...11 Monitoring Twin FHRs 120 ...
Page 126: ...12 Monitoring Triple FHRs 126 ...
Page 136: ...15 Monitoring Uterine Activity Internally 136 ...
Page 142: ...16 Monitoring FHR Using DECG 142 Testing DECG Mode Refer to the monitor s Service Guide ...
Page 154: ...18 Monitoring SpO2 154 ...
Page 164: ...20 Printing the ECG Waveform 164 ...
Page 166: ...21 Paper Save Mode for Maternal Measurements 166 ...
Page 170: ...22 Recovering Data 170 ...
Page 174: ...23 Care and Cleaning 174 ...
Page 188: ...25 Accessories and Supplies 188 ...
Page 216: ...26 Specifications and Standards Compliance 216 ...
Page 221: ...Part Number 453564290161 Printed in Germany 08 11 453564290161 ...