3 Basic Operation
31
Pop-Up Keys
Pop-up keys are context-sensitive graphical keys that appear automatically on the monitor screen when
required. For example, the
Confirm
pop-up key appears when you need to confirm a change.
Using the Touchscreen
Select screen elements by pressing them directly on the monitor's screen.
Disabling Touchscreen Operation
To temporarily disable touchscreen operation of the monitor, press and hold the
Main Screen
permanent key for about three seconds. A red padlock will blink on the
Main Screen
permanent key.
Press and hold the
Main Screen
permanent key again for about three seconds to re-enable the
touchscreen operation.
Start/ Stop
:
- start/stop manual noninvasive
blood pressure measurement
- start auto series
- stop current automatic
measurement within series
Stop All
- stop all noninvasive blood
pressure measurements
Start NBP
:
- start manual noninvasive blood
pressure measurement
- start auto series
Stop NBP
:
- stop manual noninvasive blood
pressure measurement
- stop current automatic measurement
within series
Repeat Time
- set the time interval
between two noninvasive blood
pressure measurements
Defaults
- load User Default
Sound Vol. Up
- increases the
Fetal Heart Rate volume
Sound Vol. Down
- decreases the
Fetal Heart Rate volume
Monitor Standby
- enter Standby
mode, suspends monitoring. All
numerics and waves disappear
from the display. All settings and
patient data information are
retained.
NST Report
- initiate an NST trace
interpretation and obtain a Non-
Stress Test (NST) Report
Summary of Contents for Avalon FM20
Page 2: ......
Page 8: ...8 ...
Page 56: ...3 Basic Operation 56 ...
Page 72: ...5 Alarms 72 ...
Page 82: ...6 Patient Alarms and INOPs 82 ...
Page 86: ...7 Admitting and Discharging 86 ...
Page 90: ...8 Non Stress Test Timer 90 ...
Page 120: ...11 Monitoring Twin FHRs 120 ...
Page 126: ...12 Monitoring Triple FHRs 126 ...
Page 136: ...15 Monitoring Uterine Activity Internally 136 ...
Page 142: ...16 Monitoring FHR Using DECG 142 Testing DECG Mode Refer to the monitor s Service Guide ...
Page 154: ...18 Monitoring SpO2 154 ...
Page 164: ...20 Printing the ECG Waveform 164 ...
Page 166: ...21 Paper Save Mode for Maternal Measurements 166 ...
Page 170: ...22 Recovering Data 170 ...
Page 174: ...23 Care and Cleaning 174 ...
Page 188: ...25 Accessories and Supplies 188 ...
Page 216: ...26 Specifications and Standards Compliance 216 ...
Page 221: ...Part Number 453564290161 Printed in Germany 08 11 453564290161 ...