User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
101
/
143
13.1
VCU
Status
Status:
Shows
the
current
VCU
status
100
‐
No
error
No
error,
the
desired
VCU
condition
101
‐
Line
init:
VCU
is
establishing
a
connection
to
decoders
102
‐
Sync
error
:
VCU
50
Hz
power
supply
is
not
synchronised.
103
‐
Ground
error:
Leakage
current
limit
value
exceeded
The
leakage
current
may
not
exceed
the
following
values.
More
than
0.7
A
for
8
seconds
More
than
1.0
A
for
4
seconds
More
than
1.4
A
for
2
seconds
More
than
2.0
A
for
1
second
104
‐
Load
error:
Current
consumption
of
decoder
line
is
too
high.
The
following
limit
values
may
not
be
exceeded:
More
than
2.8
A
for
32
seconds
More
than
4.0
A
for
16
seconds