background image

     

   

 

User

 

Manual

 

 

    

 

   

 

 

Bed

GK

 

1+2e

 

Rev.

 

03.04.2019

 

     

Page

 

6

 

/

 

143

 

 

2.

 

Introduction

 

 

2.1

 

What

 

is

 

Greenkeeper

 

Win?

 

 

Greenkeeper

 

Win

 

is

 

a

 

PC

computer

 

control

 

system

 

with

 

a

 

sophisticated

 

third

 

generation

 

decoder

 

system.

 

By

 

clicking

 

a

 

button,

 

the

 

programs

 

created

 

on

 

a

 

PC

 

are

 

sent

 

within

 

a

 

matter

 

of

 

seconds

 

to

 

the

 

Valve

 

Control

 

Unit.

 

From

 

there,

 

electric

 

pulses

 

are

 

transmitted

 

via

 

a

 

single

 

2

wire

 

cable

 

to

 

as

 

many

 

as

 

250

 

decoders

 

that

 

energize/deenergize

 

the

 

solenoids.

 

This

 

enables

 

you

 

to

 

avoid

 

expensive

 

installations,

 

difficult

 

modifications

 

or

 

disruptive

 

earth

 

works

 

during

 

extensions

 

as

 

well

 

as

 

all

 

costs

 

incurred

 

thereby.

 

 

Assisted

 

by

 

your

 

PC

 

and

 

the

 

Greenkeeper

 

Win

 

software

 

you

 

create

 

an

 

irrigation

 

program

 

according

 

to

 

your

 

wishes.

 

The

 

program

 

is

 

then

 

downloaded

 

via

 

the

 

serial

 

port

 

to

 

the

 

VCU.

 

 

 
 

2.2

 

Functional

 

description

 

 

The

 

Greenkeeper

 

Control

 

System

 

consists

 

of

 

the

 

following

 

components

 

(minimum

 

configuration):

 

 
 

 

1.

 

Valve

 

Control

 

Unit

 

(VCU)

 

 

 

2.

 

Windows

 

98/NT/2000/XP

 

or

 

Windows

 

7

 ‐ 

compatible

 

PC

  

  

 

with

 

a

 

modem

 

(optional)

 

 

 

3.

 

2

wire

 

decoder

 

cable

 

 

 

4.

 

Decoder

 

 

The

 

system

 

can

 

control

 

a

 

maximum

 

of

 

245

 

decoders.

 

The

 

VCU

 

feeds

 

the

 

decoder

 

with

 

modulated

 

direct

 

current

 

via

 

a

 

2

wire

 

decoder

 

cable.

 

The

 

modulated

 

direct

 

current

 

carries

 

signals

 

that

 

contain

 

information

 

for

 

the

 

decoder.

 

 

The

 

information

 

consists

 

of:

 

 

 

1.

 

Decoder

 

address

 

 

 

2.

 

Open

 

or

 

close

 

command.

 

 

The

 

brain

 

of

 

the

 

Greenkeeper

 

Control

 

System

 

is

 

the

 

PC.

 

The

 

Greenkeeper

 

Win

 

program

 

runs

 

on

 

the

 

PC.

 

The

 

master

 

data

 

for

 

the

 

complete

 

irrigation

 

equipment

 

are

 

entered

 

during

 

the

 

installation.

 

 

These

 

include:

 

 
 

 

1.

 

Rated

 

flow

 

rate

 

of

 

the

 

pump(s)

 

in

 

m³/h

 

 

 

2.

 

Water

 

consumption

 

of

 

a

 

single

 

sprinkler

 

in

 

m³/h

 

 

 

3.

 

Area

 

watered

 

by

 

a

 

single

 

sprinkler

 

in

 

 

 

Summary of Contents for Greenkeeper Feedback

Page 1: ...with Software for Windows 95 98 2000 NT XP and Windows7 User Manual Phone 49 0 7051 162 0 Perrot Regnerbau Calw GmbH E Mail technik perrot de Industriestrasse 19 29 Web http www perrot de Germany 753...

Page 2: ...ample of Pump Start with Forerunning and Interval 32 7 2 2 Example of Program End with Last running and Interval 33 7 3 Hydraulic Groups 34 7 3 1 Example of a Pipe System 35 7 3 2 Flow diagram 36 7 3...

Page 3: ...ves 89 10 2 4 Emergency call in case of pump error 89 10 2 5 Name 90 10 2 6 Phone number 90 10 2 7 Puls dial 90 11 Surveillance 91 11 1 Open graphic 91 11 2 Edit Mode 92 11 3 Graphic map selection 93...

Page 4: ...1 1 To program a decoder you need the following components 130 15 1 2 Preparation for programming the Decoder 131 15 1 3 Programming with DPG Programming unit part no ZH90022 132 15 1 4 Programming wi...

Page 5: ...or damage arising either directly or indirectly from the use of the documentation and the related programs as well as the accidental damage or consequential damage caused intentionally or due to gross...

Page 6: ...m is then downloaded via the serial port to the VCU 2 2 Functional description The Greenkeeper Control System consists of the following components minimum configuration 1 Valve Control Unit VCU 2 Wind...

Page 7: ...Option Selection field You then either type the values or select one of the proposed values in an Option Selection field Greenkeeper is the only program on the market offering a realistic graphic rep...

Page 8: ...pump relays is feasible This makes it easy to check all important parts of your system permanently The user gets quick and specific information At an early stage problems can be identified and be log...

Page 9: ...r printer The operating system OS has to be completely installed and configured Ask your PC supplier to confirm the PC requirement profile COM 1 for VCU Valve Control Unit COM 2 for modem optional Nev...

Page 10: ...accordance with BA 10119 The earth resistance should be less than 10 Ohm In poor conductivity areas gravel or sand 2 x 20 m earth conductors should be used Mount a potential equalizing bar on a wall i...

Page 11: ...3 This will be dealt with in greater detail later The red LED must not be lit up If the red LED lights up a faulty decoder cable is indicated Please double check all cable and decoder connections 3 2...

Page 12: ...Computer Ready for Installation Check first which interfaces are available by Windows XP Do that like descripted as following Click Start Customize Control Panel Left mouse click on the symbol Control...

Page 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...

Page 14: ...a a serial port RS 232 A standard PC computer has two serial ports available The first I O port is marked COM1 Communication Port 1 The second I O port is marked COM2 Communication Port 2 To each I O...

Page 15: ...N coded socket Therefore use the left hand side socket Do not use the right hand side socket which may be disconnected For other countries consult your telephone company Using the cable connect now th...

Page 16: ...panel opens In this window click on Phone and Modem All the modems installed will be listed in this window You can view the modem properties in this window Note the Port field in the Properties windo...

Page 17: ...order Monitor Modem if available Printer if available Computer When Windows are up and running you can start with the installation of the Greenkeeper software Proceed as follows Take the Greenkeeper C...

Page 18: ...d GK 1 2e Rev 03 04 2019 Page 18 143 The Setup Wizard is preparing the installation This is the Welcome screen Should you want to terminate the installation click Cancel Click Next to continue with th...

Page 19: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 19 143 The Setup program proposes a directory for the installation Confirm the directory by clicking Next once...

Page 20: ...04 2019 Page 20 143 Click on Next to continue with the installation Here you can review all information once again Should you want to make changes just click Back By clicking Cancel you have the opti...

Page 21: ...019 Page 21 143 To confirm the settings as they are click Next and the installation will continue After all the installation disks have been copied the Setup Wizard arranges the data in folders Click...

Page 22: ...generated If this is not the case Clock on the Start button Choose in the menu programs Clock on GK Win and move it to the desktop The icon is generated 4 4 Graphics Installation You can use up to 10...

Page 23: ...per Win You can start the Greenkeeper Win in 2 different ways By double click on the icon at the desktop Move the mouse pointer on the Greenkeeper Win icon and double click By the Windows program list...

Page 24: ...osition the mouse pointer on Ok and click it once with the left mouse button This is the menu bar From here you can control Greenkeeper Win The menus that are available to you depend on the Password L...

Page 25: ...cation setup limited Change active programs This Password Level provides you with everything you need for the control of Change Active Programs To change the Password Level position the mouse pointer...

Page 26: ...llowing Password Levels are available 6 1 Password Level 1 medium security Password you will receive it from the System Administrator Can be changed by the System Administrator Access to menus All Exc...

Page 27: ...d will be given to the System Administrator during installation Access to menus All With this password you can change or delete all relevant data in Greenkeeper Win Please be careful when you log on u...

Page 28: ...hydraulic group and a hydraulic sector Water consumption of a valve The above data is specified during installation by the installer of the irrigation system and is duly recorded Do not change any da...

Page 29: ...e System Configuration menu click Pump data hydraulic groups and sectors The data entry window opens Use this window to enter pump as well as hydraulic group and hydraulic sector specific data As a ru...

Page 30: ...t Not installed The pump is not installed and will be not considered by the system Passive The pump is installed but used for different purposes e g as a service pump It will not be considered by the...

Page 31: ...ere Values 0 30 seconds Only possible when more than one pump is used The Interval is a pause in seconds between the activation deactivation of two pumps When the system is under full load 5 pumps the...

Page 32: ...res The interval runs again Pump 1 starts after the interval expires Now Forerunning runs The first valve opens after Forerunning expires Second Operation 0 Program starts Pump 5 starts 20 Interval 20...

Page 33: ...h the lowest number is always switched off first The interval runs now Pump 3 stops after the interval expires The interval runs again Pump 5 stops after the interval expires Seconds Operation 0 Last...

Page 34: ...arrangement and pipe dimensions While in terms of irrigation efficiency it would be bad practice to supply the valves that are in operation simultaneously from the same pipe branch pressure drop it is...

Page 35: ...on the green to be in operation simultaneously However as the pipe supplying Green 1 would be overloaded while the other lines remain unused the resulting pressure drops would be excessively high For...

Page 36: ...up Setup Here you can define hydraulic groups Each group is assigned a letter from A to I This means you can define a maximum of 9 hydraulic groups Calculate the maximum flow taking into account the p...

Page 37: ...igned a number from 1 40 Later you will only refer to a particular number Click in the Flow m field and type the required flow in m After clicking in another field the values entered will be saved The...

Page 38: ...ic groups and sectors must be higher than or identical with the flow rate of the valves assigned to them If a value is entered that is lower you will receive an error message Code 023 xxxx invalid flo...

Page 39: ...l valve data is entered and stored here Here the serial number of the valve is shown which is identical with the actual decoder number Here you can change the order in which the individual valves are...

Page 40: ...xxx is already used the valve name has already been used Code 006 xxx exceed valid length the valve name is too long max 8 characters When entering valve names always start with the name of the area t...

Page 41: ...e to a hydraulic sector here The sector will then be assigned to a hydraulic group Value range 1 40 No assignment 0 NOTE A hydraulic sector can only be used with a hydraulic group The hydraulic groups...

Page 42: ...hydraulic group or sector assigned to the valve Here it will be defined if it is a normal or a bi direction decoder A x represents a bi directional decoder X bi directional decoder Empty normal decode...

Page 43: ...st be updated and retested Finally all retested programs can be downloaded to the VCU 7 6 System Data Max weather station stop time Should the irrigation be stopped by the weather station the station...

Page 44: ...y required when more than one pump is controlled by the pump decoder The pump manager which is a part of this program adapts the pump capacity to the water consumption of the irrigation system The upd...

Page 45: ...This represents the time how often in the irrigation cycle the average should be calculated depending on the current flow of the valve The 60 sec flow of the valve is the decisive factor for an optima...

Page 46: ...ump has to be controlled by the pump decoder the pump manager of the Greenkeeper is acting in that way that the flow capacity of the activated pumps meets the required flow of the irrigation system as...

Page 47: ...ed to the VCU Closer digital input 1 VCU terminal 11 12 These terminals are used for inputs from the weather station Opener digital input 2 VCU terminal 13 14 These terminals are used for inputs from...

Page 48: ...auge Range 0 20 mA Q I analogue input VCU terminal 23 24 This input is used for an anemometer Range 0 20 mA Frequency 1 2 VCU terminal 15 16 17 18 These are two additional inputs designed as frequency...

Page 49: ...urrent values for the analogue inputs 1 to 4 When the sensor is connected according the above sketch the measured current value is shown under Analogue 2 If there is no pressure applied to the pressur...

Page 50: ...n front of the figure Offset 6 24 Now we have done all necessary inputs Greenkeeper is currently measuring the actual pressure These values are reported in the menu actual irrigation report and weathe...

Page 51: ...C above in this example 4m h per mA will be typed in the Scale entry field for S5 in the External VCU interface dialog box Offset 999 9 to 999 9 This is a correction value affecting only the Scale fa...

Page 52: ...e for the interface to respond type the required value in the Limit field Should these values be exceeded irrigation will be stopped suspended As soon as the values get within the limit again irrigati...

Page 53: ...Analogue connection 1 Scale factor 5 0 Offset value 1 0 Limit range 20 x 5 0 1 0 101 0 The limit range is then 0 0 101 0 Example Frequency connection 1 Scale factor 0 6 Offset value 1 0 Limit range 1...

Page 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...

Page 55: ...Control There are two Remote Control options 1 VCU Remote This function allows you to control a remote VCU from your computer To facilitate the VCU and the PC must be connected with a modem 2 Remote...

Page 56: ...t be connected to this port Value range COM 1 6 Default COM 2 Baud rate A baud is the unit of signalling rate 1 Bd 1 s i e a measure of signal changes that take place in a transmission channel during...

Page 57: ...Modem Commands Initialization String Description AT Attention Modem control command The AT prefix tells the modem that AT commands are sent to the modem F Recall factory default configuration This is...

Page 58: ...ll be loaded Default Y1 Profile 1 will be loaded Qn Enable Disable Modem Responses Using this command you can disable the responses that the modem sends to the connected computer either completely Q1...

Page 59: ...D3 W This initialization string allows the modem to establish a connection to a remote VCU AT F S0 0 E0 V1 Y0 Q0 D3 W The only difference is in the S0 command 7 11 Backup Restore Data BACKUP YOUR DAT...

Page 60: ...all select which type of data you want to backup As a rule it may be system data and program data Click Backup system data and Backup program data The selected data is marked with a tick Select the ba...

Page 61: ...ll receive the following information Acknowledge the message by clicking OK Your data has been stored on the data storage medium you have selected Exit the Backup dialog box by clicking OK To restore...

Page 62: ...een successfully restored you will receive the following message Acknowledge the message by clicking OK Your data has been successfully restored You can now exit the Backup restore dialog box by click...

Page 63: ...eeper only supports changing the font itself You cannot change the font size or colour It is recommended to use the default font Arial 7 12 2 Copying the graphic from the data medium on the hard disc...

Page 64: ...he graphic file here The graphic files are used as the background picture in the Surveillance menu The graphic depicts the irrigated area a golf course etc It must be stored in the bitmap format bmp A...

Page 65: ...utton the following window is displayed You have the option of selecting up to 10 different graphic files bitmap Click in the empty NAME field The Select picture dialog box with the graphic files will...

Page 66: ...ly click Open The file name will be automatically inserted in the Name field Type a description of the graphic For example Green1 6 etc To delete a graphic file from the list click Clear The file name...

Page 67: ...ev 03 04 2019 Page 67 143 7 12 4 User Passwords Level 1 You can change the existing password for Level 1 and Level 2 here Level 2 Changes can only be made if you are currently in Password level 3 Ok S...

Page 68: ...ved The sequence of valve opening is determined by the program It is however possible to change the sequence 2 Sectors In this program all the valves within a pre defined sector open taking into consi...

Page 69: ...g order should the sequence be explicitly entered The Flow Manager provides for the optimum pump loading Select the Single valves option by clicking it with the left mouse button To create a new progr...

Page 70: ...gram the following window opens Your program name is displayed her Position For information only sequence numbers defined in the Valve data dialog box Valve name For information only valve name Sequen...

Page 71: ...ective fields Time Enter the required valve open time 0 479 minutes The duration entered is used to automatically calculate precipitation Consumption For information only the calculated water consumpt...

Page 72: ...nfigurations Click Program test A program configuration that you created will be checked and made ready for a download to the VCU Without going through the test a program cannot be downloaded to the V...

Page 73: ...the hard disk To make the program executable you must download it to the VCU Refer to Chapter 9 Downloading 8 2 Sectors For this program type it is necessary that you pre define the sectors Go to Prog...

Page 74: ...unique name and assign the valves to the sectors A valve can only be assigned to one sector Confirm the entry by clicking Ok 8 2 1 Creating a Sectors Program Go to Program configuration Water program...

Page 75: ...the whole sector is displayed in the Consumption field The Flow Manager takes into consideration one sector only After the first sector has finished the next sector starts You can enter the sequence i...

Page 76: ...tion to multiple sectors For example if you enter G in the Enter valve search text field all sectors that start with G will be assigned the same precipitation Click Ok to exit the dialog box Ok Save t...

Page 77: ...ou can do this by creating a manual program Programming procedure Select pump s Select and assign valves to program steps Specify duration of each step Run program test Exit programming window Downloa...

Page 78: ...mp efficiency is displayed here Make sure the pumps are used effectively Incorrect data can lead to pump damage There are always 8 steps displayed in the Manual program window Scroll this bar to displ...

Page 79: ...ld a delay have been defined in System configuration General the valves within a step will start in intervals equal to the delay entered Once the first valve within a step closes the first valve withi...

Page 80: ...12 13 42 0 5 On T1 12 13 48 0 6 Off G2 12 13 27 0 7 On T2 12 13 33 0 8 Off G3 12 13 12 0 9 On T3 12 14 18 0 10 Off T1 12 18 12 0 11 On F1 12 18 39 0 12 Off T2 12 18 33 0 13 On F2 12 18 60 0 14 Off T3...

Page 81: ...sign in the Position column indicates that the program has already been downloaded to the VCU The right hand side area shows the programs that are currently available on the VCU In the example above o...

Page 82: ...nd the position number will be marked with an arrow Click Ok The program is now available in the VCU and ready for activation Both versions of the program must be identical A change in the program is...

Page 83: ...ard disk Once a program has been removed from the VCU it cannot be invoked from Change Active Programs But as the program remains stored on the hard disk it can be at any time downloaded to the VCU ag...

Page 84: ...isplayed Active A program is currently running Do not make any changes when in the active status Stopped A control program has been stopped However the program continues to run internally Waiting Chan...

Page 85: ...ms The same procedure applies to the first and second week Single If you want a program to be removed from Change Active Programs after it has been invoked for the first time click the Single field to...

Page 86: ...ng the Correction field Consumption The calculated consumption for each program is shown here You can change Consumption using the Correction field Start irrigation This will bring the VCU to the wait...

Page 87: ...rigation The following dialog box will be brought up Select your program and confirm your choice by clicking Ok The selected program will start immediately The following box will appear in the top sec...

Page 88: ...e number of the alarms e g valve open fault exceeded the entered limit the entire irrigation will be stopped Every active program will be stopped all manual opened valves will be closed The correspond...

Page 89: ...status relays is closed and the decoder reports following status Coil shortcut xx Ohm This means the pump system has an error If decoder 245 reports an error the entire irrigation stops each active pr...

Page 90: ...check any phone number If you call from an extension line it s necessary to add a 0 in front of the phone number Ask your telephone administrator 10 2 7 Puls dial Here the dialling method will be det...

Page 91: ...click Surveillance Surveillance picture The graphic will load automatically The top bar of the screen displays the following information Irrigation status Running program Calculated pump flow The cal...

Page 92: ...r placing valve symbols Click the Edit mode button The Select valves window will pop up The window lists all valves that have not been placed To place a valve position the mouse pointer over the valve...

Page 93: ...n a valve by clicking the valve symbol Enter the valve open time from 1 99 minutes The default value is 15 minutes Click OK to open the valve selected 11 4 Pump management The system will then start a...

Page 94: ...e following dialog box is displayed All manually open valves are displayed in the list To close a valve again click the valve symbol The valve will close and it will be removed from the list The Close...

Page 95: ...1 Irrigation report This report shows the total precipitation and water consumption for each valve for the current and previous year 2 Actual watering report This report shows all valve activities fr...

Page 96: ...s Actual watering report This report shows valve activation data from the last 15 irrigation programs As only a total of 15 reports can be stored the oldest report with the highest Report No is always...

Page 97: ...I pressure gauge If a pressure gauge is connected the actual pressure in bars is displayed here Print Hardcopy of the report displayed on the printer Previous report Previous report only when more tha...

Page 98: ...please click Reporting System error status Following status can be displayed OK green no error FEHLER red error NA grey no FB decoder installed If there is an error in the irrigation system it will be...

Page 99: ...rwards click in the new window on the RESET button If you want to delete several error messages in one step click with the left mouse button at RESET DECODER LOG and confirm this afterwards in the new...

Page 100: ...ctions VCU version information The current VCU software version is displayed here VCU version update For downloading a new software version to the VCU Reset VCU error To send commands to the VCU After...

Page 101: ...power supply is not synchronised 103 Ground error Leakage current limit value exceeded The leakage current may not exceed the following values More than 0 7 A for 8 seconds More than 1 0 A for 4 seco...

Page 102: ...deenergised Output 2 Relay output 2 energised deenergised LED 1 yellow Irrigation program status ON Irrigation program running BLINK Program stopped by weather station SHORT BLINK Running program sto...

Page 103: ...No 241 upwards decoder open Red Decoder activated manually Blue Decoder activated by irrigation program White Decoder activated automatically and manually F1 Open Decoder Activate decoder open valve...

Page 104: ...stored in Flash PROM memory It can happen that for example when you are updating the program you will also need to update the software After the chipset update the yellow LED of the VCU may not be fl...

Page 105: ...e Rev 03 04 2019 Page 105 143 Click the Pe_main hex file The file name will automatically appear in the File name field Click Open Here you can watch the download status To download the VCU program cl...

Page 106: ...uld the deleting process last an extremely long time approx 50 s the computer has been disconnected from the VCU Click Cancel to abort the downloading Refer to troubleshooting Should this not be possi...

Page 107: ...the top line you can follow the overall progress One after the other Layers 1 7 and then the Base Layer will be transferred After the Base Layer has been transferred the complete VCU program is stored...

Page 108: ...decoder line for a short circuit Clear VCU memory The VCU memory is completely deleted All the VCU values are reset to default values All reports are deleted All programs are deleted Clear VCU reports...

Page 109: ...n carry out a decoder or decoder valve test you must first select the decoders valves in the Selected valves box Position the mouse pointer over the valve name and click it with the left mouse button...

Page 110: ...seconds after a decoder has been activated the current consumption of the decoder line is measured and compared with the reference value The difference is recorded in the decoder current A field Shoul...

Page 111: ...nsmitter even when it is disconnected from the decoder control system On energising a valve through the transmitter only Pump 1 Decoder No 246 is started automatically The remaining pumps must be acti...

Page 112: ...as been successfully downloaded to the transmitter 13 6 2 Transmitter Status Transmitter Ready The transmitter is properly connected and is ready to download data Transmitter Busy The transmitter is r...

Page 113: ...e plug has to be connected with the field connector The transmitter provides following functions Valve open Valve immediately clos All valves immediately close The transmitter will be connected with t...

Page 114: ...all European countries without radio license Application The WT is very robust and easy to use with just 5 buttons Ideal for manual watering and for function tests of the system Functions Open and cl...

Page 115: ...ommunicator complies with this requirement For operating Nokia Communicator please refer to the product s instruction manual There must be installed a licensed newDIALin software in the Nokia Communic...

Page 116: ...ure that this telephone line is not used for normal voice telephone calls Take your Nokia Communicator and dial the number of the telephone line on which the computer with Greenkeeper has been install...

Page 117: ...ommunicator Before initial operation you must assure that the newDIALin Software is installed Press control key Extras topside right after open the Communicator Move cursor with help of the arrow key...

Page 118: ...lephone you can now put in the connecting number with that number the modem will be connected for example to 07051 162100 Note There is the possibility to reset wrong input with help of the key backsp...

Page 119: ...D MENU 16 01 12 12 22 17 Remote password level Password Level 3 Change remote password level by pressing Enter Using the key select the Main menu PERROT REGNERBAU REMOTE TERMINAL MAIN MENU 16 01 12 12...

Page 120: ...MENU 16 01 12 12 22 15 Enter new password ______________________ Type the password and press the ENTER key Password level 0 allows you to access the Password menu only Password level 1 allows you to...

Page 121: ...ning a valve Press the ENTER key Using the keys move the cursor to the required valve and press the ENTER key Type the valve open time Then press again the ENTER key The system automatically starts a...

Page 122: ...ading to the VCU the xxxxx program has been updated Delete the xxxxx program on the VCU and repeat the download from the PC to the VCU See Downloading programs Download program Press the 1 key The sys...

Page 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...

Page 124: ...To view the next 6 programs press the 2 key For the 6 previous programs press 3 You can store as many as 99 programs on your hard disk Programs on VCU Here you can view all the programs that are curre...

Page 125: ...ou can enter a maximum of 4 different programs with 3 start times each On entering a program that already exists the following error message will be issued Code 008 xxxxx is already used Should this h...

Page 126: ...tus shows the current status of the VCU The following status information is displayed Active A program is currently running Do not make any changes when in the active status Stopped A control program...

Page 127: ...gram can be started provided the weather station does not inhibit irrigation 2 Stop This will stop suspend the program However the program and the duration continue to run internally After the program...

Page 128: ...error has been detected 101 Line init If this message shows up the decoder line is being initialised Once the initialization is finished a message follows 100 to 105 102 Sync error The decoder line ca...

Page 129: ...Decoder 15 1 Programming of Decoder Attention Only in Password level 3 Before a new decoder is installed an address number must be programmed into it Decoder numbers 1 240 are reserved for valves Onl...

Page 130: ...ng of Decoder The only external difference of the FB decoder is the rectangular housing Standard decoder square housing Description of FB decoder Type PD F 1 part no ZH90384 The description of the new...

Page 131: ...se Connect the cable of the programming unit to the terminals 34 35 on the VCU terminal strip Therefore you have to disconnect the connector from the decoder cable Start the Greenkeeper program using...

Page 132: ...steadily Press the switch into position program on the programming unit earliest after 2 seconds to confirm the address Now the decoder should give 5 short flashes Should this not be the case repeat t...

Page 133: ...in order to confirm the address Now the decoder should give 5 short flashes Should this not be the case repeat the procedure starting with item 3 Note With the programming cable it is not possible to...

Page 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...

Page 135: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 135 143 15 1 6 Decoder List Decoder Area Number and type of the Flow Irrigated Hydr No Name rotors m h Area m Sector...

Page 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...

Page 137: ...in alphabetic fields Code 006 s exceed valid length Your entry has too many characters Reduce the number of characters Code 007 length of the name is too short The name you selected is too short Enter...

Page 138: ...de 016 VCU Storage limit exceeded The VCU program memory is full Remove programs and or reports you no longer need from the VCU Code 017 VCU Unknown program name The program selected is not stored in...

Page 139: ...e 029 No valves No valve names have been selected Choose the valve names Code 030 No valves in sector s No valves have been assigned to the sector Code 031 s not present in program Code 032 Pump flow...

Page 140: ...he VCU have been exceed Delete the programs you no longer need from the VCU Max 12 single valves sectors programs and max 8 manual programs Code 044 s invalid program Code 045 s invalid start time Cod...

Page 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...

Page 142: ...9 file s is missing on restore disk Call the service engineer Code 060 Port not available to remote transmitter change settings Code 061 Step s No step time You have not entered step time for a step i...

Page 143: ...DIR DECODER Decoder no 245 reported a pump alarm Eliminate the error in the pump system and delete the error See chapter 12 107 Decoder failure ONLY FOR BI DIR DECODER The accepted number of errors e...