104
‐
Load
error
The
current
consumption
of
the
decoder
line
is
too
high.
Check
all
decoders
and
the
decoder
line
for
short
‐
circuits,
etc.
When
the
load
current
exceeds
a
given
value
the
VCU
is
switched
into
error
mode.
You
must
reset
the
VCU
using
the
Service
menu
–
Reset
VCU
error
option.
Check
the
surroundings
for
earthwork
being
carried
out.
Decoder
line
fault.
105
‐
Volt
error
Decoder
line
voltage
is
too
low.
Check
the
decoder
line.
Call
the
service
engineer.
106
‐
Pump
alarm
(ONLY
FOR
BI
‐
DIR
‐
DECODER)
Decoder
no.
245
reported
a
pump
alarm.
Eliminate
the
error
in
the
pump
system
and
delete
the
error.
See
chapter
12
107
‐
Decoder
failure
(ONLY
FOR
BI
‐
DIR
‐
DECODER)
The
accepted
number
of
errors
exceeded.
Check
the
decoder,
solenoids,
etc.
and
delete
afterwards
the
error
messages.
See
chapter
12
108
‐
Decoder
check
(ONLY
FOR
BI
‐
DIR
‐
DECODER)
The
accepted
number
of
errors
from
the
FB
‐
decoder
is
not
exceeded.
Check
the
decoder,
solenoids,
etc.
and
delete
afterwards
the
error
messages.
See
chapter
12
Subject
to
change
without
prior
notice.
We
remain
at
your
full
disposal
for
any
further
information
you
may
require!
REGNERBAU
CALW
GmbH
Industriestrasse
19
‐
29
75382
Althengstett
/
Germany
Tel.
+49
/
7051
/
162
‐
0
http://www.perrot.de
Summary of Contents for Greenkeeper Feedback
Page 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Page 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Page 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Page 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Page 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...