User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
31
/
143
Enter
forerunning
here.
In
the
broadest
sense
also
the
delay.
Values:
0
‐
250
seconds
.
After
the
start
of
the
last
pump
the
opening
of
the
first
valve
is
delayed
by
the
Forerunning
entered.
Example:
Pump
1
starts........5
s
forerunning
.......first
valve
opens.
Enter
the
pump
interval
here.
Values:
0
‐
30
seconds
Only
possible
when
more
than
one
pump
is
used.
The
Interval
is
a
pause
in
seconds
between
the
activation
/
deactivation
of
two
pumps.
When
the
system
is
under
full
load
(5
pumps)
the
Interval
will
be
employed
4
times.
Enter
last
running
of
the
last
pump
here.
Values:
0
‐
100
seconds
.
Last
running
is
a
period
of
time
during
which
the
pump
continues
running
after
the
valve
is
closed.
NOTE:
Depending
on
Forerunning
and
Interval
in
extreme
cases
it
can
take
up
to
370
seconds
before
the
first
valve
opens!
Summary of Contents for Greenkeeper Feedback
Page 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Page 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Page 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Page 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Page 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...