User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
53
/
143
The
limit
range
is
calculated
using
the
scale
factor
and
the
offset
value
in
System
configuration
–
General.
Max.
input
value
x
Scale
+
Offset
=
Limit
range
The
max.
input
value
is:
In
analogue
inputs:
20
mA
In
frequency
inputs:
1000
Hz
Example
:
Analogue
connection
1
Scale
factor
=
5,0
Offset
value
=
‐
1,0
Limit
range
=
20
x
5,0
+
1,0
=
101,0
The
limit
range
is
then
0,0
–
101,0
Example:
Frequency
connection
1
Scale
factor
=
0,6
Offset
value
=
1,0
Limit
range
=
1000
x
0,6
–
1,0
=
559,0
The
limit
range
is
then
0,0
–
559,0
A
negative
offset
value
must
be
added.
A
positive
offset
value
must
be
deducted.
NOTE:
Never
enter
the
offset
value
as
the
limit
value.
The
smallest
changes
would
then
cause
the
irrigation
program
to
be
stopped
by
the
weather
station.
Summary of Contents for Greenkeeper Feedback
Page 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Page 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Page 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Page 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Page 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...