User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
79
/
143
Manual
programs
operation
is
governed
by
the
following
rules:
If
no
delay
has
been
entered
in
System
configuration
/
General,
the
steps
will
start
one
after
the
other.
Once
the
first
step
finishes
(or
the
first
valve
within
the
step
closes)
the
first
valve
of
the
next
step
starts.
Should
a
delay
have
been
defined
in
System
configuration
/
General
,
the
valves
within
a
step
will
start
in
intervals
equal
to
the
delay
entered.
Once
the
first
valve
within
a
step
closes,
the
first
valve
within
the
next
step
opens.
When
the
second
valve
within
a
step
closes,
the
second
valve
within
the
next
step
opens,
etc.
This
means
that,
between
the
individual
steps,
the
valves
overlap.
However,
this
is
only
possible
if
a
value
(max.
30
seconds)
has
been
entered
in
System
configuration
/
General
/
Manual
Control
Program
Overlap
.
(See
Chapter
7.6)
Summary of Contents for Greenkeeper Feedback
Page 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Page 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Page 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Page 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Page 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...