Connecting Accessories
107
2020 is equipped with a standard 10.6 eV UV lamp. An 11.7 eV
UV lamp (Part No. MX390024) available for special applications.
Install this lamp as outlined in
Removing and Replacing the UV
Lamp
on page 116. When you install a UV lamp other than the
standard 10.6 eV lamp, all the response factors become invalid. You
must set the response factor for the current cal memory to 1.
Contact the Applications Department for further information.
NOTE:
Do not use the 11.7 eV lamp in conjunction with the dilution
probe.
Limitations of Lithium Fluoride Lamp
Window
This lamp is intended for special applications only. It is not suitable
for normal operation, due to limitations of the lamp window material.
The 11.7 eV lamp window material is lithium fluoride (LiF). LiF is
composed of two light elements which are easily disrupted within the
crystal lattice by the UV light generated by the lamp. Disruption of
the lattice causes the crystal to turn a yellowish color, and again
performance declines.
Unlike other lamp windows, LiF readily absorbs water from
atmospheric humidity. When contaminated by moisture, the window
loses its ability to transmit UV light. Clean the lamp window as
outlined in
Cleaning the Lithium Fluoride Window
on page 120.
NOTE:
Do not touch the lamp window or handle it near liquid water.
Using the 11.7 eV UV Lamp
With an 11.7 eV lamp installed, your instrument functions as a leak
detector responding to gases and vapors which ionize at 11.7 eV or
less. The 11.7 eV lamp may be useful for detecting leaks of
chemicals not ionized by the standard 10.6 eV lamp.
Summary of Contents for Photovac 2020
Page 2: ......
Page 3: ...Photovac Model 2020 Portable Photoionization Detector...
Page 5: ...Reference No 600762 Rev E...
Page 6: ......
Page 13: ...Notices and Warnings...
Page 14: ......
Page 23: ...Introduction 1...
Page 24: ......
Page 38: ......
Page 39: ...Tutorial Session 2...
Page 40: ......
Page 51: ...Tutorial Session 49 Mode on page 62 for details of switching between display modes...
Page 60: ...2020 Software Manual 58 the datalogger or at the end of the datalogger will free usable space...
Page 67: ...Tutorial Session 65...
Page 68: ......
Page 69: ...Detailed Operation 3...
Page 70: ......
Page 88: ...2020 Software Manual 86...
Page 89: ...Connecting Accessories 4...
Page 90: ......
Page 115: ...Routine Maintenance 5...
Page 116: ......
Page 126: ...2020 Software Manual 124...
Page 127: ...Troubleshooting 6...
Page 128: ......
Page 153: ...Troubleshooting 151...
Page 154: ......
Page 155: ...Technical Description 7...
Page 156: ......
Page 163: ...Appendices 8...
Page 164: ......
Page 181: ...Appendices 179...