C2 Commissioning
Hydraulic oil
■
Observe DGUV [German Statutory
Accident Insurance] regulation 113-
020.
■
Top up the hydraulic oil when the
climbing device is in a retracted posi-
tion.
■
Observe the hydraulic oil viscosity/
temperature diagram.
■
Refer to the details for the appropri-
ate operating temperature and vis-
cosity of the hydraulic unit in the
manufacturer’s assembly instructions.
Hydraulic hoses
Observe DGUV [German Statutory Ac-
cident Insurance] regulation 113-020.
■
Maintenance and checking of hoses.
■
Notes on laying hose lines.
■
Notes on storage.
■
Period of use.
Minimum bending radius (internal
measurement) as per DIN EN 853:
■
Hose DN08: 115 mm
■
Hose DN10: 130mm
■
Hose DN12: 180mm
■
Do not mix different hydraulic oils.
■
Make a note of the oil type used for
filling (e.g. on oil card).
■
If the oil type is changed, the pumps,
climbing devices and hoses need to
have an oil change.
Areas of application for PERI hydraulic oils in combination with Hydrau-
lic Unit RCS MAX 2 x 210bar, 380-460V
Name
Temperature range
Cold start required under
Hydraulic oil ISO 11158 HM10
-20 °C ... +25 °C
–
Hydraulic oil ISO 11158 HVI22
-14 °C ... +50 °C
-5 °C
Hydraulic oil ISO 11158 HVI46
±0 °C ... +70 °C
+10 °C
In general, use PERI hydraulic oils within viscosity range 16 to 400 mm²/s. A cold start
is required from 200 mm²/s.
Hydraulic unit
Observe the manufacturer’s assembly
instructions for the maintenance and
repair of the hydraulic unit.