![Pepperl+Fuchs IC-KP-B17-AIDA1 Manual Download Page 98](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930098.webp)
2014-
02
98
Web features
Mail address sender
Enter an email address associated with the device here. The email server may have to
recognize the address, depending on the SMTP server.
IP address smtp server
IP address of the SMTP server
Mail triggered on channel by error codes:
Status information is allocated to each response telegram. If this value does not match the error
code entered for the relevant channel, an email is issued. An error code should not be entered
for channels that are not connected to a R/W head. The field should also remain empty if a
trigger sensor is connected to a channel. If more than one error code is entered, the codes
must be separated with a comma. A maximum of 5 different codes is permitted.
The following error code entries are recommended:
■
6 - Hardware error
■
7 - Internal device error
Subject:
The comment entered in this line appears in the subject line of every email that is sent.
Additional e-mail text:
Enter any text here that you wish to include in each email that is sent. The device adds the
channel, the type designation of the R/W head, and the cause of the error that has occurred to
this text.
8.4
Security settings
User name, password:
The default user name and password is: "identcontrol."
Note!
Use the vacant box to specify a location or enter serial information, for example.