![Pepperl+Fuchs IC-KP-B17-AIDA1 Manual Download Page 13](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930013.webp)
Product Description
2014-
02
13
4.4
Displays and Controls
The following displays and controls are located on the control interface.
LEDs
Description Function
Status description
CH1
CH2
CH3
CH4
Status display for the
read/write heads
LED illuminates
green
as soon as there is an active
command on the read/write head.
LED illuminates
yellow
for approx. 1 second as
soon as a command is executed successfully.
PWR/ERR Status display for
IDENTControl
LED illuminates
green
as soon as the
IDENTControl is connected to a power supply and
the interface is ready for operation.
LED illuminates
red
as soon as there is a hardware
error or a PROFINET name has been assigned and
no PROFINET connection has been established.
LED flashes
green
as soon as a signal has been
sent to the IDENTControl via the "Flashing"
PROFINET function or if there is an internal data
overflow.
Link1/Link2 Connection to the network
for channel 1/channel 2
LED is off until initial communication is made via
Ethernet.
LED illuminates
green
as soon as a connection to
the network is established.
Traffic
Network activity
LED flashes
green
as soon as the IDENTControl
sends data.
Display
Two-line multifunction display with 12 characters per line for displaying different status and
operating information and four pictograms for displaying connected reading heads.
Push buttons
Push buttons are used for controlling the display and selecting commands when programming
the control interface.
Return to higher level
Up menu item
Down menu item
RETURN (confirm input)
Link1
Link2
Traffic
CH1
CH2
CH3
CH4
Control
IC-KP-B17-AIDA1
ESC
ESC