Commissioning
2014-
02
21
6.3
Device settings
You must set the various parameters prior to commissioning.
The parameters are volatile and non-volatile parameters. Volatile parameters are reset to their
default setting when the system is switched off and on again.
Non-volatile parameters
Volatile parameters
Configure the read/write station with the described system commands. "99" is preset as the
data carrier type.
Warning!
Device not configured or configured incorrectly
Configure the device prior to commissioning. A device that has not been configured or
configured incorrectly may lead to faults in the plant.
Parameters
Default setting
Value range
General
Multiplex mode
Off
On / off
R/W head
Trigger mode
Off
On / off
Data carrier type
99
00 ... FF
Ethernet interface
MAC address
00:0D:81:xx:xx:xx
00:0D:81:xx:xx:xx
DHCP
Off
On / off
IP address
169.254.10.12
yyy.yyy.yyy.yyy
Standard gateway
169.254.254.1
yyy.yyy.yyy.yyy
Subnet mask
255.255.0.0
yyy.yyy.yyy.yyy
Assembly inst. out
100d
100d ... 112d
PROFINET device name
Empty
Free text
Data hold time
50d x 10 ms
0d ... 255d x 10 ms
Parameter
Default setting
Value range
R/W head
Password mode
Off
on / off
Password
00000000
00000000 ... FFFFFFFF