Commands
2014-
02
85
<ByteNum> = 0h deletes this filter.
fill tag (S#)
Command:
Response:
The word number <WordNum> of fill signs <Fill Sign> is written to the read/write tag from the
specified start address <WordAddr>.
Extended commands for type IDC-... and IUC
…
tags
Type IDC-...-1K tags can be programmed to read 24-bit information (so-called
special read
only code)
very quickly. This is useful for detecting containers in automated warehouses.
Note!
The TI command only adjusts a setting in the reading head. There is no HF communication
with the read/write tags.
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
1)
Telegram length, high byte
0
0
0
0
0
0
0
0
Byte 1
1)
Telegram length, low byte
0
0
0
0
1
0
0
1
Byte 2
Command code (AAh)
1
0
1
0
1
0
1
0
Byte 3
Reserved/Ident channel/Toggle
bit
<Reserved>
<Channel>
<T>
Byte 4
Start address
<WordAddr> (high byte)
Byte 5
Start address
<WordAddr> (low byte)
Byte 6
Word count
<WordNum> (high byte)
Byte 7
Word count
<WordNum> (low byte)
Byte 8
Character
<Fill Sign>
1)
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
1)
Telegram length, high byte
0
0
0
0
0
0
0
0
Byte 1
1)
Telegram length, low byte
0
0
0
0
0
1
1
0
Byte 2
Command code (AAh)
1
0
1
0
1
0
1
0
Byte 3
Reserved/Ident channel/Toggle
bit
<Reserved>
<Channel>
<T>
Byte 4
Status
<Status>
Byte 5
Reply counter
<ReplyCounter>
1)
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
Length of the
special read only code
:
■
Tag of the type IDC-...-1K:
48 bit
■
Tag of the type IUC:
96 ... 240 bit