![Pepperl+Fuchs IC-KP-B17-AIDA1 Manual Download Page 64](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930064.webp)
2014-
02
64
Commands
reset (RS)
Command:
This command terminates all active commands. The device settings are reloaded from the
non-volatile memory.
This confirmation is issued for this command (status FFh) instead of a response. The device
resets the hardware and then restarts.
set multiplexed mode (MM)
Command:
Response:
This command switches multiplex mode on and off. In multiplex mode, the R/W heads are
controlled according to the time multiplex process, i.e. only one R/W head is active. The
procedure minimizes mutual interference between R/W heads, allowing two R/W heads to be
mounted side by side.
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
1)
Telegram length, high byte
0
0
0
0
0
0
0
0
Byte 1
1)
Telegram length, low byte
0
0
0
0
0
1
0
0
Byte 2
Command code (16h)
0
0
0
1
0
1
1
0
Byte 3
Reserved/Channel/Toggle bit
0
0
0
0
0
0
0
<T>
1)
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
1)
Telegram length, high byte
0
0
0
0
0
0
0
0
Byte 1
1)
Telegram length, low byte
0
0
0
0
0
1
0
1
Byte 2
Command code (9Bh)
1
0
0
1
1
0
1
1
Byte 3
Reserved/Toggle bit
0
0
0
0
0
0
0
<T>
Byte 4
Multiplex mode
0
0
0
0
0
0
0
<F>
1)
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
1)
Telegram length, high byte
0
0
0
0
0
0
0
0
Byte 1
1)
Telegram length, low byte
0
0
0
0
0
1
1
0
Byte 2
Command code (9Bh)
1
0
0
1
1
0
1
1
Byte 3
Reserved/Toggle bit
0
0
0
0
0
0
0
<T>
Byte 4
Status
<Status>
Byte 5
Reply counter
<ReplyCounter>
1)