Commissioning
If you intend to use a DHCP server, you must select the "Use DHCP" option on the web page.
See chapter 8.2
6.5.1
Using the identification system without a DHCP server
The following parameters must be set manually on the web page.
■
DHCP-OFF
1)
■
IP address
1)
■
Subnet mask
1)
■
Gateway address
1)
■
Assembly inst. Out
1)
■
PROFINET device name
■
Data hold time
1)
1)
: Parameters can also be set manually via the display.
See chapter 8.2.
6.5.2
Using the identification system in conjunction with a DHCP server
In this case, the parameters of a DHCP server are assigned to the identification system.
However, if an IP address is not assigned to the device, the corresponding settings on the
DCHP server must be configured accordingly.
The identification system ignores the permanent IP address, subnet mask and gateway
address parameters preset in the device.
Note!
We recommend using a fixed preset IP address in order to avoid system malfunctions.
Caution!
Always use parameters that you know are compatible with your network.