Range of application
The system is suited for the following applications:
■
Automation
■
Material flow control in production
■
Acquisition of operating data
■
Access control
■
Identification of storage vessels, pallets, work piece carriers, refuse containers, tanks,
containers, etc.
4.2
Device characteristics
■
Up to 4 R/W heads can be connected
■
Alternatively up to 2 R/W heads and 2 trigger sensors can be connected
■
LCD indicator with background illumination
■
Direct operation using 4 function keys
■
LED status indicator for bus communication and R/W heads
4.3
Product Family
The brand name IDENTControl represents a complete identification system. The system
consists of an IDENTControl control interface with bus interface, inductive read/write heads
(125 kHz and 13.56 MHz), read/write heads with electromagnetic coupling (UHF with 868
MHz) and the associated read only and read/write tags in a number of different designs.
IDENTControl is open and can be connected to other identification systems.
The system is equally well suited for use in the switching cabinet and for field use in IP67. The
interface to the controlling fieldbus is integrated into the enclosure and all connections are
implemented as plugs. This enables simple installation and quick, correct replacement in case
of device failure. The consistent EMC design (metal enclosure, grounding, shielded wires)
offers a high degree of noise immunity. Function buttons are available for parameterization and
entering commands directly into the IDENTControl.
4.3.1
R/W heads
There are different R/W heads available for the IDENTControl in different designs. Depending
on your particular application, you can connect inductive R/W heads (125 kHz and 13.56 MHz)
or R/W heads with electromagnetic coupling (UHF with 868 MHz).
4.3.2
Read Only Tags/Read/Write Tags
Read only / read/write tag 125 kHz (inductive)
A wide range of read only and read/write tag designs are available for this frequency range,
from a 3 mm thin glass tube to a transponder 50 mm in diameter. Read/write tags are available
for temperatures up to 300
°
C (max. 5 min) in chemical-resistant housings for installation in
metal and in degree of protection IP68/IP69K. IPC02-... read only tags offer 40-bit read only
codes. IPC03-... read/write tags have a 928-bit freely programmable memory bank and an
unmodifiable 32-bit read only code. You can define 40-bit read only codes with IPC11-... read
only tags. You can use these as permanent read only codes or continually redefine them.