![Pepperl+Fuchs IC-KP-B17-AIDA1 Manual Download Page 113](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930113.webp)
Appendix A
2014-
02
113
A response appears in the input field:
Ele-
ment
Implicit
telegram
Use
Contents Description
1
Byte 0 Command code
04h
Command
CT
(Change tag)
Byte 1 Number of double words/
Channel/Toggle bit
02h
Channel = element = 1
Toggle bit = 0
Byte 2 Status
00h
Command executed.
Byte 3 Reply counter
02h
For every IDENT telegram, the
value on the reply counter
increases by 1.
Byte 4
00h
Byte 5
00h
Byte 6
00h
Byte 7
00h
2
Byte 8 Command code
04h
Command
CT
(Change tag)
Byte 9 Number of double words/
Channel/Toggle bit
04h
Channel = element = 2
Toggle bit = 0
Byte 10 Status
00h
Processing command.
Byte 11 Reply counter
02h
For every IDENT telegram, the
value on the reply counter
increases by 1.
byte 12
00h
Not used
Byte 13
00h
Not used
Byte 14
00h
Not used
Byte 15
00h
Not used
3
Byte 16
...
Byte 23
00h
No commands are transmitted
to channel 3.
4
Byte 24
...
Byte 31
00h
No commands are transmitted
to channel 4.
Note!
The input and output instances can be configured via the display. However, setting should be
performed via the program while the plant is operating to permit easier replacement or
extension to the plant.