![Pepperl+Fuchs IC-KP-B17-AIDA1 Manual Download Page 107](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930107.webp)
Appendix A
2014-
02
107
A response appears in the input field:
Send a Change tagcommand to channel 3 as an implicit command:
A command confirmation appears in the input field:
A response appears in the input field:
Byte no.
Use
Contents Description
Byte 0
Command code
04h
Command
CT
(Change tag)
Byte 1
Number of double words/
Channel/Toggle bit
02h
Channel = 1
Toggle bit = 0
Byte 2
Status
00h
Command executed.
Byte 3
Reply counter
02h
For every IDENT telegram, the value
on the reply counter increases by 1.
Byte 4
...
Byte 11
00h
Byte no.
Use
Contents Description
Byte 0
Command code
04h
Command
CT
(Change tag)
Byte 1
Channel/Toggle bit
06h
Channel = 3
Toggle bit = 0
Byte 2
Tag type (high byte)
30h
IPC 02
Byte 3
Tag type (low byte)
32h
IPC 02
Byte 4
...
Byte 11
00h
Byte no.
Use
Contents Description
Byte 0
Command code
04h
Command
CT
(Change tag)
Byte 1
Number of double words/
Channel/Toggle bit
06h
Channel = 3
Toggle bit = 0
Byte 2
Status
FFh
Processing command.
Byte 3
Reply counter
03h
For every IDENT telegram, the value
on the reply counter increases by 1.
Byte 4
...
Byte 11
00h
Byte no.
Use
Contents Description
Byte 0
Command code
04h
Command
CT
(Change tag)
Byte 1
Number of double words/
Channel/Toggle bit
06h
Channel = 3
Toggle bit = 0
Byte 2
Status
00h
Command executed.
Byte 3
Reply counter
04h
For every IDENT telegram, the value
on the reply counter increases by 1.
Byte 4
...
Byte 11
00h
Note!
Alternatively select the tag type by configuring the relevant setting in the boot-up object.