Commands
2014-
02
37
Third step
A
read holding registers
- MODBUS command must be executed. The registers contain the
response to the executed identification command
enhanced read
.
Address
(0-based)
Register division
Byte number of the
identification
telegram
Use
Contents
Meaning
2000d
High byte
Reserved
00h
-
Low byte
Utilization register
06h
6 % of the FIFO
memory is utilized
2001d
High byte
Byte 0
Length of the
identification
telegram from this byte
onwards
00h
-
Low byte
Byte 1
Length of the
identification
telegram
06h
6 bytes long
2002d
High byte
Byte 2
Command code
04h
change tag
command
Low byte
Byte 3
Reserved/Channel/
Toggle bit
04h
4 corresponds to
channel 2. Channel
number shifted 1 bit to
the left.
2003d
High byte
Byte 4
Status
00h
00h = command
executed (meaning of
the identification
statuses see chapter
Low byte
Byte 5
Reply counter
01h
Increases by 1 after
each additional
response.
2004d -
2011d
High byte
-
00h
-
Low byte
-
00h
-
Table 7.11
Responses to the executed identification command
change tag
Address
(0-based)
Register division
Byte number of the
identification
telegram
Use
Contents Meaning
2000d
High byte
Reserved
00h
-
Low byte
Utilization register
03h
3 % of the FIFO
memory is utilized
2001d
High byte
Byte 0
Length of the
identification
telegram from this byte
onwards
00h
-
Low byte
Byte 1
Length of the
identification
telegram
06h
6 bytes long