— Chapter 9. Configuring the Repeater
PES1900NR Operations Manual
152
High Battery Alarm
Indicates that the battery voltage of the BUPS is above operating tolerances, and the BUPS
cannot power the repeater.
Charger Fail Alarm
Indicates that the internal charger of the BUPS has failed, and the BUPS is unable to
recharge its batteries.
UPS Summary Alarm
Indicates that one or more of the BUPS alarms have triggered. UPS Tamper Alarm indicates
that the door of the BUPS is open.
3. Click the down-arrow next to an
Alarm
field, to select one of the following alarm severity
settings:
•
Disabled
•
Event
•
Minor
•
Major
•
Critical
4. Click
the
Apply
or
OK
button.
•
The
Apply
button changes the alarm severity setting, and keeps the
UPS Properties
screen open.
•
The
OK
button changes the alarm severity setting, and closes the
UPS Properties
screen.
Monitoring Repeater Status
The subsystem
Status
screens monitor and control various repeater system functions. By clicking
the appropriate subsystem icons, you can check each subsystem in the repeater.
Each Status screen includes one or more of the following tabs:
Alarms Tab
Reports present subsystem alarm states, with date and time stamps.
Measurements Tab
Reports power and operational temperature measurements, including Low and High values. A Reset
Low/High button resets the values.
Voltages Tab
Reports present voltages for a subsystem.
Control Tab
Includes ON/OFF switches for internal and external subsystem hardware.