PES1900NR Operations Manual
Chapter 9. Configuring the Repeater — 151
Growth Box Input Power Alarm
The input power to the growth box is out of system tolerances.
Growth Box Power Supply Alarm
The internal system power of the growth box is out of tolerances.
3. Click the down-arrow next to an
Alarm
field, to select one of the following alarm severity
settings:
•
Disabled
•
Event
•
Minor
•
Major
•
Critical
4. Click
the
Apply
or
OK
button.
•
The
Apply
button changes the alarm severity setting, and keeps the
Power System
Properties
screen open.
•
The
OK
button changes the alarm severity setting, and closes the
Power System
Properties
screen.
Backup Power System (UPS)
Properties
The
UPS Properties
screen
provides the initial configuration
settings for the optional Back-Up
Power Supply (BUPS), which is
external to the repeater.
1. From the menu bar in the
Main Control screen, select
Configuration
->
UPS
.
The
UPS Properties
screen opens (see
Figure 137).
2. Use
the
Alarms Setting
tab
to redefine alarm severity
for the backup power
systems.
The Alarm Setting tab sets
the alarm severity for the
following alarms:
AC Fail Alarm
Indicates that the input power to the BUPS has failed. Depending on which BUPS model is
installed at the repeater site, the BUPS will then provide 40 or 80 amp-hours of backup power
for the repeater, before shutdown. The AC source powers the charger. Low Battery Alarm
Indicates that battery voltage for the BUPS is below operating tolerances, and the BUPS
cannot power the repeater.
Figure 137 UPS Properties Screen,
Alarm Setting Tab