Manual
80
8.3.12 Tutorial for the use of splices
If you want to measure an object which is longer than the effective length of the laser measurement
system, you need to divide it (only on paper) into individual sections (splices), which do not exceed the
effective length (refer to the following picture).Keep in mind, that the minimal amount of measurement
points should not be less than 3 and at least one more than the amount of overlap points (minimal
amount of overlap points is 2). At the beginning, you need to carry out rough laser alignment for the first
splice. If the measurements for the current splice are finished, move the transmitter as close to the
overlap point as possible. Carry out rough laser alignment for the next splice and start the measurement.
Place the receiver on the first overlap point. Check the display for the correct numbers of the point and
the splice. The correlation of point number, splice and overlap point is shown in the following picture as
well.
In this example, we divide the object into two splices. The first splice possesses 5 measurement points
(positions) and the second splice possesses 6 measurement points including the overlap points. In the
beginning, you need to collect the receiver values of the first slice (from Point 1 to Point 5). Move the
transmitter to its next position (Yellow Square). Carry out rough laser alignment for the second splice.
Note:
Point 1 on the second splice has the same physical position on the object as Point 4 in the first splice.
Point 2 on the second splice has the same physical position on the object as Point 5 in the first splice.
The distance between Point 2 and Point 3 on the second splice is the distance between Point 5 on the
first splice and Point 3 on the second splice so that this distance after the first splice contributes to the
total length in the following.
8.3.13 Live Mode
Place the receiver on this position to carry out a live measurement on the selected position. Turn the
result screen into the reference line mode and in the table view now. Select the required plane with
and
and press
, to get to the measurement screen, where you can activate the live mode.
Press
another time, to start the live mode.
Do not move any objects, until a blinking „LIVE MODE“ appears!
Move the object to the zero direction with the help of the measurement values on the screen. To stop the
live mode and receive the result, press
.
First splice from Point
1 to Point 5
Transmitter position for the
measurement of the second
splice
Intentional overlap of the Points 4
and 5 of the first splice with the
points 1 and 2 of the second
splice
Second splice from Point 1 to Point 6
with the Points 1 and 2 as overlap points
(repeated measurement of the points)