Manual
23
7.1.4
Result
To display the result of the measurement, push
, if you are located in the measurement screen or
push
, if you are located in the “horizontal alignment” option.
What should be noted in this window
Shortcuts in this window
Do not rotate the shaft, while
moving the machine.
Entry of misalignment tolerances
Do not change the position of the
measurement unit, while Live Mode
is activated
Functions in this window
Spacer simulation
-
View the calculated misalignment
-
Carry out Live Alignment
-
Pause/continue Live Mode
-
Manual entry of the angle (if
activated)
-
Selection between 2 or 3 decimal
digits
-
Selection of the measurement unit
(mm/inch)
-
Entry of tolerances
-
Entry of thermal growth
-
Save the alignment results
-
Load the alignment results
-
Spacer simulation
For flange correction view (just vertically)
Selection between 2 or 3 decimal digits
Manual entry of the angles (if activated). In this
case, you need to interrupt the Live mode and
enter the angle afterwards.
If the cursor is in the first place of an entry field,
push the button twice, to reverse sign
Entry of thermal growth
Selection of the measurement unit (mm/mils)
Interrupt/continue Live Alignment
Save the alignment results to a file (see
chapter 10
„Handling of the Data Dialogue
window“
)
Load results from file (see
chapter 10
„Handling of the Data Dialogue window“
)
Symbols and status in this screen
A yellow dial in the alignment screen means that the angle
of the measurement points is not accepted or that
averaging is not completed. The Live Alignment mode is
deactivated in this case.
A red half of a coupling means that the current
misalignment is out of the tolerance limits. If the
misalignment is within these limits, the symbol is displayed
in grey colour.
A blinking checkbox in the headline of the particular plane
means that Live Alignment can be used for this plane.
Otherwise, this is not possible for the particular plane.
This blinking error report means that the position of the
shaft was changed unexpectedly. The Live Alignment
mode will be deactivated. To activate it again, press
to
pause it and then
again to continue.