Manual
25
7.1.5.4
Carry on working after the position of the sensors has been changed
Before you continue with the alignment, after the position of the sensors has been changed, you need to
place the sensors in two predefined positions (3/9
o’clock and 6/12 o’clock). A notification describing the
procedure will appear. Do not forget to enter the angle manually, if this option is activated. If the sensors
have been placed in a predefined position, the next step is automatically continued after a short setting
time. If the shafts are already set, the setting time can be skipped by pressing
.
After the first step is finished (e.g. 3:00 /9:00 position), the position indication changes with the note for
the second step (e.g. 6:00/12:00 position).
After the second step is finished as well, the note and the yellow dial vanish and the Live Alignment
process starts.
7.1.5.5
Entry of tolerances
To enter tolerances, press
Functions in this window
Shortcuts in this window
-
Selection of industry standard tolerances via
the RPM selection
-
Manual tolerance entry
Adjust tolerances via RPM (rotations
per minute)
Manual entry of tolerances
If the RPM selection is activated:
Raise RPM by one step.
If manual entry is activated:
Select parallel misalignment
If RPM selection is activated:
Reduce RPM by one step.
If manual entry is activated:
Select angular misalignment entry
Save and exit
Note
Displays the
predefined positions
If the shafts are
already set, press
to skip
Notification