background image

Manual 

94 

 

11 

„My Documents“ option  

 

Functions in this window 

Shortcuts in this window 

Find/organize files and folders 

 

Save reports as a .pdf-file 

 

 

 

Find/organize folders and files, 
create new folders, delete folders 
and files 

 

Save the report as .pdf-file 

 
 

 

 
 

11.1  Find/organize folders and files 

To find/organize folders and files, press 

 
 

Functions in this window 

Shortcuts in this window 

Find folders and files 

 

Switch between internal storage and SD card 

 

Delete folders  

 

Delete files 

 

Create a new folder 

 

 

 

If the folder and file list is 
selected: 
Navigate through the list 
 
If the storage medium selection 
field is selected:  
Selection between SD card and 
internal storage (“My 
documents”) 

 

Navigate a step up in the folder 
hierarchy  

 

If the folder and file list is 
selected: Delete folders or files 

 

If the folder and file list is 
selected: Create a new folder 

 

 

Switch between folder and file 
list and the storage medium 
selection field 

Summary of Contents for TU 3

Page 1: ...ts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instru...

Page 2: ...7 7 1 2 Change parameters 18 7 1 3 Data acquisition 19 7 1 4 Result 23 7 1 5 Live Alignment 24 7 2 Vertical machine alignment 28 7 2 1 Entry of machine dimension 29 7 2 2 Change add parameters 30 7 2...

Page 3: ...re line programme 68 8 2 1 Short explanation 68 8 2 2 Main screen of the program configuration of planes and changing of parameters 68 8 2 3 Configuration process 69 8 2 4 Carry out measurement 70 8 2...

Page 4: ...data transfer of the sensor 89 9 5 Set the user language 90 9 6 Set USB mode 91 10 Handling of the Data Dialogue window 92 11 My Documents option 94 11 1 Find organize folders and files 94 11 2 Save a...

Page 5: ...rms they can be found in our general terms of business If you have any questions please contact PCE Instruments 2 1 Precautions The PCE TU 3 is a class II laser system with a typical wavelength of 670...

Page 6: ...tion 0 01 or 0 001 mm Inclinometer Resolution 0 1 Interface USB Bluetooth Memory 2 GB Functions Horizontal alignment in every position from 60 to 360 Vertical alignment Auto sweep mode Adjustable tole...

Page 7: ...lignment 3 Detector target 4 Exit hole of the laser beam 5 Horizontal alignment Front and top view of the measurement sensors 1 Reference point 2 Cable connector socket Measurement sensor side view 1...

Page 8: ...centre lines of the shaft need to be concentric during normal operation 4 2 1 CE Conformity The Shaft alignment tool is conforming to the following CE requirements 2006 95 EC EN 61010 1 2001 EN 60825...

Page 9: ...n and efficiency with the machine operator After that you need to determine the arrangement of correction planes Stationary machines S The position of the machine is not changed in the course of measu...

Page 10: ...ows machine S from the point of view of machine M from 12 o clock position The surfaces of the measurement sensors are marked as S and M and should be mounted to the corresponding shaft of the machine...

Page 11: ...an the surface of the laser detector and the exit hole of the sensor if necessary Use a cotton pad soaked in alcohol for the cleaning Do not use solvents for the cleaning under any circumstances Check...

Page 12: ...e 2 Sensor S 3 Sensor M 4 Moveable machine F1 Front machine base F2 Rear machine base S M distance between the measurement sensors S C distance between sensor S and the middle of the coupling S F1 dis...

Page 13: ...al alignment 1 Moveable machine 2 Stationary machine S M distance between the measurement sensors S C distance between sensor S and the middle of the coupling S F1 distance between sensor S and the al...

Page 14: ...o middle of the detector 4 Alignment of the moveable machine M in order to make sure the laser beams meet S and M in the middle Rotate the shaft with the measurement sensors to the 9 00 position Aim t...

Page 15: ...data entry main screens of programs and some other 6 2 Starting the PCE TU 3 Having completed the booting the main menu appears on the display To select a menu item press if the battery indication is...

Page 16: ...le with the Bluetooth adaptor kit What should be noted in this window Shortcuts in this window Firstly carry out the Soft Foot Measurement to avoid unexpected errors during the alignment check the res...

Page 17: ...indow Navigate down Enter distance sensor S middle of the coupling Enter distance sensor S sensor M Enter distance sensor S middle of the coupling Enter distance sensor S front machine base Enter dist...

Page 18: ...s in this window Activate deactivate manual angle entry Manual entry or use of the sensor data Manual angle entry or data from integrated inclinometer Selection between 2 or 3 decimal digits Selection...

Page 19: ...on twice to reverse sign Select the measurement unit mm or inch Set parallel misalignment Offset Save all data in one file see chapter 10 Handling of the Data Dialogue window Load data from file see c...

Page 20: ...llow indictaion means that the rotation angle is over 60 A green indication means that the rotation angle is over the recommended area over 90 This symbol means that an expanded Y value range is used...

Page 21: ...tector opening figure front and top view of the sensor side view of the sensor If the laser beams aim both detectors open the covers The X Y coordinates and the position von S and M are now displayed...

Page 22: ...phase Adjust the laser beam until the value becomes 0 and wait for 5 seconds Push to save the Offset value After you have left the Offset menu the symbol appears to display the Offset settings Select...

Page 23: ...r the angle afterwards If the cursor is in the first place of an entry field push the button twice to reverse sign Entry of thermal growth Selection of the measurement unit mm mils Interrupt continue...

Page 24: ...hould be enabled for the required plane indicated by a blinking checkbox in the plane headline Loosen the machine bases now and start the adjustment with the help of the calculated corrective values 7...

Page 25: ...9 00 position the position indication changes with the note for the second step e g 6 00 12 00 position After the second step is finished as well the note and the yellow dial vanish and the Live Alig...

Page 26: ...ment extension Enter vertical parallel misalignment extension Enter vertical angular misalignment extension Navigate up through the entry fields Navigate down through the entry fields If the cursor is...

Page 27: ...base F1 Entry of the thickness of the rear machine base F2 Remaining misalignment Navigate up through the entry fields Navigate down through the entry fields Save and exit Measurement unit Horizontal...

Page 28: ...luetooth interface only with optional Bluetooth adaptor What should be noticed in this window Shortcuts in this window Check the result after the alignment by measurement again Determine new data Func...

Page 29: ...ent results the following must be respected S C S F1 S F2 Navigate up through the entry fields Functions in this window Navigate down through the entry fields Enter distance sensor S middle of the cou...

Page 30: ...digits Manual entry or use of the sensor data Selection between 2 or 3 decimal digits Selection of the measurement unit mm inch Alignment to the X and Y coordinates simultaneously or just to the Y coo...

Page 31: ...tion entry if activated Selection of measurement unit mm inch Navigate through collected data Delete add replace measured values Restart all values are deleted Set Offset Enter Ym values if manual ent...

Page 32: ...n be deleted or replaced If this sign is not displayed in the window the current value has not been saved yet Pressing you can store the value The absence of the laser beam position indicator and a re...

Page 33: ...ationary and moveable side Manual angle Note Box Dial with measurement points and the graphically displayed angles Entire rotation angle needs to be larger than 60 Laser beam position indication Seria...

Page 34: ...r the other to the middle of the detector opening figure front and top view of the sensor side view of the sensor If the laser beams aim both detectors open the covers The X Y coordinates and the posi...

Page 35: ...d phase Adjust the laser beam until the value gets 0 and wait for 5 seconds Push to save the Offset value After you have left the Offset menu the symbol appears to display the Offset settings Select f...

Page 36: ...and enter the angle afterwards If the cursor is in the first place of an entry field push the button twice to reverse sign Entry of thermal growth Selection of the measurement unit mm mils Pause cont...

Page 37: ...nt with the help of the calculated corrective values in the 9 3 plane 6 12 plane Live Alignment To start the 6 12 plane Live Alignment the sensors should be located in the 6 or 12 o clock position If...

Page 38: ...o close the window press once again Before you continue working after the position of the sensors was changed you need to place the sensors in two predefined positions Proceed as described in 7 1 5 4...

Page 39: ...olerances via RPM rotations per minute Manual entry of tolerances If the RPM selection is activated Raise RPM by one step If manual entry is activated Select parallel misalignment If RPM selection is...

Page 40: ...e feet Save results to a file see chapter 10 Handling of the Data Dialogue window Firstly enter the machine dimensions just as described with the horizontal alignment or skip the process by pressing a...

Page 41: ...refore please do refer to chapters 7 1 Horizontal machine alignment and 5 5 Rough alignment The differences to these chapters are described in the following Drive Shaft main menu What should be noted...

Page 42: ...indow Shortcuts in this window Enter distance sensor S sensor M Enter distance front machine base rear machine base Navigate up Navigate down Switch between measurement units mm mils Save and exit Mac...

Page 43: ...e manual data entry Functions in this window Activate deactivate manual angle entry Manual entry or use of the sensor data Manual angle entry Selection between 2 or 3 decimal digits Selection between...

Page 44: ...gnment To start the program select machine train and press The main screen of the program will appear What should be noted in this window Shortcuts in this window Similar to the horizontal alignment a...

Page 45: ...or to scroll through the complete train press to enter the dimensions for the machine of the current coupling Press to change the parameters see chapter 7 1 2 Change parameters press to determine misa...

Page 46: ...th are always valid for the left shaft or machine Zoom in Zoom out Define the current machine as reference machine Save results to a file see chapter 10 Handling of the Data Dialogue window Open pop u...

Page 47: ...art the Spindle Program select Spindle in the main menu and press The main screen of the Spindle Program will appear Current machine Current machine number Machine which is currently selected as stati...

Page 48: ...Mark two points on the machine bed near and far where the receiver shall be placed on the tool slide for future measurement Enter the distance between the near and the far measurement point Mount the...

Page 49: ...nment of a spindle are available after all four measurements were carried out To leave the current screen press To leave the Spindle Program press again To save the results press refer to chapter 10 H...

Page 50: ...ieve results which are as accurate as possible you should carry out alignment very carefully due to planes Plan your measurement placing the transmitter in the first position 12 o clock and confirm th...

Page 51: ...l shafts Functions in this window Enter amount of measurement points positions Create modify view points Change parameters Enter dimensions Start measurement View results available if all required mea...

Page 52: ...distance to the next point Repeat the process until all distances are entered To change parameters press The parameter screen will appear To activate or deactivate the manual data entry press To acti...

Page 53: ...ng data if activated Manually entering of the receiver value H Manually entering of the angle necessary for the position confirmation Switch between measurement units Open context menu Carry out or re...

Page 54: ...int number 1 and reference point number 2 Press to confirm In order to delete a reference point enter as the value Best Fit Mode in this mode the result is the difference between the calculated best f...

Page 55: ...rry out measurement Manual data entry if activated Switch between table and graph illustration Define reference point use to confirm your entry Switch reference point mode Save Repeat measurement all...

Page 56: ...Manual 56 Ref Point Mode Best Fit Mode Red indicates that tolerance is exceeded...

Page 57: ...e points where the receiver shall be placed Align the laser towards X and Y direction within 0 5 mm and start the Flatness Program Use the S or M sensor as a receiver The receiver should be placed wit...

Page 58: ...alue for averaging and confirm with To get to the Auto Router settings press Press to save and leave the screen 8 1 3 1 Auto Router The Auto Router can be deactivated or configured in the two followin...

Page 59: ...to enter a value for the total width length or line column spacing Every time you change the total width length the values for the line column spacing are recalculated and vice versa The grid is defi...

Page 60: ...d to be entered Change the line ring position of the line ring which the selected point belongs to Functions in this window Change the position of the column which the selected point belongs to Change...

Page 61: ...ote Zahl bedeutet dass mehr Zeilen Spalten existieren und per Scrolling abgerufen werden k nnen Line position Selected point Column position Change line position Change column position Add line bottom...

Page 62: ...re ready before carrying out another measurement sandglass symbol must not be blinking Delete selected point Functions in this window View result Carry out measurement at the selected point Delete the...

Page 63: ...olumn Receiver X axis value Laser beam position indicator Selected point Blinking symbol means that laser beam is out of aim Measured point Empty point Receiver Y axis value Inclinometer Sensor temper...

Page 64: ...11 Reference modes There are three reference modes you can select between by pressing 8 1 11 1 No reference plane The result is an unchanged receiver value 8 1 11 2 Laser Plane If no reference points...

Page 65: ...s in the Laser Plane mode 8 1 13 Result modes There are three different modes to view the results Original Values are shown as positive and negative values All positive Values are shown relative to th...

Page 66: ...lue Peak Peak peak to peak value Average average value Std deviation standard deviation value Tolerance tolerance value The coloured bar on the bottom of the screen shows error percentages and the amo...

Page 67: ...Manual 67 2 points in the positive over reference red range 3 points in the negative under reference yellow range...

Page 68: ...Shortcuts in this window The required dimensions should be entered correctly can be changed later on if recommended measurement data will not be influenced Start a new measurement Functions in this wi...

Page 69: ...er for the particular plane To do that press and enter the particular value for the current plane If you want to change parameters press to get to the parameter screen Here you can activate deactivate...

Page 70: ...or serial the connection establishment can take between 2 and 30 40 seconds It is recommended to wait about 10 seconds cable connection or about 50 seconds wireless connection If no connection is esta...

Page 71: ...ried out to calculate the result Save as many measurements as possible max 36 in order to receive a result as accurate as possible The minimum rotation angle amount of the particular rotations between...

Page 72: ...Press to save In order to delete the reference points enter the value Best Fit Mode In this mode the result is the difference between the calculated best fit reference line and the detector value The...

Page 73: ...he component towards zero with the help of the measurement values on the screen To stop the Live Mode and to receive the result after the movement press Do not stop the Live Mode if the measurement va...

Page 74: ...data will not be influenced Start a new measurement Functions in this screen Enter number of measurement points positions Create modify view point Create modify view Part Splice Change parameter Ente...

Page 75: ...cessary to carry out a straightness measurement of the whole object correctly If the effective length of the laser is longer than the measured object there is no need to use parts splices Overlap poin...

Page 76: ...ss to reach the parameter screen Here you can activate deactivate the manual data entry by pressing or the manual angle entry by pressing Pressing makes it possible to switch between the measurement u...

Page 77: ...to the receiver with the help of the adjustment screws on the transmitter once again The laser beam should aim the middle of the receiver again Move the receiver to the first measurement point Be sur...

Page 78: ...e line and the receiver value To define reference points press and enter reference point number 1 and reference point number 2 Press to confirm In order to delete a reference point enter as the value...

Page 79: ...o return to the main screen Number of the calculated points including overlap points distance Overlap points Point number and splice number Splice number is only displayed when splices are used Yellow...

Page 80: ...t 1 to Point 5 Move the transmitter to its next position Yellow Square Carry out rough laser alignment for the second splice Note Point 1 on the second splice has the same physical position on the obj...

Page 81: ...ceive on the selected position press and after that to start the Live Mode for the next selected plane The alignment of a point can influence other points Repeat the measurements after using the Live...

Page 82: ...be noted in this window Shortcuts in this window All required dimensions should be entered correctly can be changed later on if recommended Start new measurement or repeat measurement all collected da...

Page 83: ...wards Carry out measurements for Point 3 and Point 4 now The RL 20 laser transmitter must not be moved after the beginning of the measurement Be careful when you turn the laser beam The order of measu...

Page 84: ...e results press To return to the main screen of the program press If you want to enter tolerances press If the calculated results are out of your tolerance range the vertical plane is illustrated incl...

Page 85: ...ieve firmware version and status information Set language Set USB mode Set date and time Configure automatic turn off View set up program licences Set data transfer to the sensor Set user language Set...

Page 86: ...s in this window Shortcuts in this window Navigate left between the fields Navigate right between the fields Increase the current value Decrease the current value Move between the fields cyclically Le...

Page 87: ...ow Setting of the turn off time in seconds Note 1 To deactivate auto turn off set the time to zero or leave the box blank Note 2 If the values below 30 seconds are entered the box is highlighted in ye...

Page 88: ...esman If he sends you the license file copy it to the My documents folder on your instrument or to the SD card and insert it To load this file press and a loading dialog appears Use the arrow keys to...

Page 89: ...etween Bluetooth and serial interface Configure Bluetooth interface Slave Device Number Select Bluetooth interface Select serial interface If Bluetooth is activated Use a sensor via Bluetooth Use both...

Page 90: ...al 90 9 5 Set the user language To set the user language press Functions in this window Shortcuts in this window Change user language Navigate through available languages Save and exit Exit without sa...

Page 91: ...Microsoft Active Sync 4 5 to get access to the device Do not start any loading or saving processes on the device while the device is used via USB in mass storage mode Functions in this window Shortcut...

Page 92: ...options The My documents folder internal always available The Storage Card folder external SD card only available if an SD card is inserted General structure of the Data Dialogue window Folder and fi...

Page 93: ...t is selected and you are at a subfolder Navigate a step up in the folder hierarchy If folder and file list is selected Delete the selected folder file Caution If folder and file list is selected Crea...

Page 94: ...tcuts in this window Find folders and files Switch between internal storage and SD card Delete folders Delete files Create a new folder If the folder and file list is selected Navigate through the lis...

Page 95: ...If the storage medium is selected Selection between SD card Storage Card and internal storage My documents Move up a step within the folder hierarchy If the folder or file list is selected Delete fil...

Page 96: ...hese tolerances RPM Good Acceptable Parallel misalignment Angular misalignment Parallel misalignment Angular misalignment Up to 1000 0 08 0 07 0 12 0 10 Up to 2000 0 06 0 05 0 10 0 08 Up to 3000 0 04...

Page 97: ...se them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 14 Contact If you have any questions about our range...

Page 98: ...4 D 59872 Meschede Deutschland Tel 02903 976 99 0 Fax 02903 976 99 29 info pce instruments com www pce instruments com deutsch Bedienungsanleitung Lasermeter PCE TU 3 Version 1 1 Erstelldatum 06 11 2...

Page 99: ...ndern 15 6 1 3 Daten sammeln 16 6 1 4 Ergebnis 19 6 2 Vertikale Maschinenausrichtung 24 6 2 1 Maschinenabmessungen eingeben 25 6 2 2 Parameter ndern hinzuf gen 25 6 2 3 Daten sammeln 26 6 2 4 Ergebni...

Page 100: ...nd Parameter ndern 66 7 3 2 Messungen durchf hren 68 7 3 3 Ergebnisse betrachten und speichern 70 7 3 4 Tutorial zur Teilst ckbenutzung 72 7 3 5 Live Modus 72 7 4 Rechtwinkligkeitsprogramm Squareness...

Page 101: ...it einer typischen Wellenl nge von 670 nm einer Leistung von 1 MW und einer maximalen Strahlungsenergie von 0 1 mJ pro Impuls Der Klasse II Laser erf llt die Anforderungen nach ANSI BS 4803 IEC 825 un...

Page 102: ...2004 108 EC EN 61326 1 2006 EN 61326 2 2 2006 EN 55011 2009 A1 3 2 Technische Spezifikationen und Funktionen Sensortyp positionssensible Photodioden 10 x 10 mm Lasertyp sichtbar rot 635 670 nm 1 MW Ma...

Page 103: ...fang Das PCE TU 3 Messsystem beinhaltet 1x PCE TU 3 Displayeinheit 2x Messsonden 2x Montage Sets f r die Messsonden 1x Ma band 1x Ladeger t 1x Anschlusskabel 1x Software CD ROM 1x USB Kabel 1x Bedienu...

Page 104: ...hrer ob eine Umpositionierung der beweglichen Maschine M m glich und unter Bedienungs und Effektivit tsgesichtspunkten sinnvoll ist und bestimmen Sie dann die Anordnung der Korrekturebenen Station re...

Page 105: ...ustieren Sie die Position der Maschinenf e an der beweglichen Maschine anhand der ermittelten Korrekturwerte auf dem Display Achtung F r die Durchf hrung der Messung ist es wichtig sich an der Rotatio...

Page 106: ...usreichend 4 2 Einrichtung des Ger tes Bevor Sie mit dem Ger t arbeiten kontrollieren Sie den Batteriestatus und laden Sie die Batterie falls n tig Der Batteriestatus wird als kleines farbiges Bild un...

Page 107: ...wischen den Messsensoren S C Abstand zwischen Sensor S und Mitte der Kupplung S F1 Abstand zwischen Sensor S und Maschinenfu F1 S F2 Abstand zwischen Sensor S und Maschinenfu F2 muss gr er sein als S...

Page 108: ...Bild 8 Drehen Sie die Welle mit den Messsensoren in die 9 Uhr Position Zielen Sie mit den Lasern auf die Mitte der geschlossenen Detektor ffnung Drehen Sie die Welle mit den Messsensoren auf die 3 Uh...

Page 109: ...rammen und einige andere 5 2 Das PCE TU 3 starten Nach dem Hochfahren erscheint das Hauptmen auf dem Display Im Hauptmen W hlen sie einen Men punkt und dr cken Sie Wenn die Batterieanzeige unten im Di...

Page 110: ...it optionalem Bluetooth Adapter Kit Zu beachten in diesem Bildschirm Shortcuts in diesem Bildschirm F hren Sie zun chst eine Kippfu Messung Soft Foot durch um unerwartete Fehler w hrend der Ausrichtun...

Page 111: ...1 S F2 Navigieren nach oben Funktionen in diesem Bildschirm Navigieren nach unten Strecke Sensor S Kupplungsmitte eingeben Strecke Sensor S Sensor M eingeben Strecke Sensor S vorderer Maschinenfu eing...

Page 112: ...eingabe aktivieren deaktivieren Manuelle Eingabe oder Verwendung der Sensordaten Manuelle Winkeleingabe oder Daten aus integriertem Neigungssensor Auswahl zwischen 2 oder 3 Nachkommastellen Auswahl zw...

Page 113: ...e Eingabe aktiviert ist Winkel eingeben wenn manuelle Winkeleingabe aktiviert ist Wenn der Cursor sich an erster Stelle in einem Eingabefeld befindet dr cken Sie die Taste zweimal um ein negatives Vor...

Page 114: ...zu klein ist geringer als 6 Eine hellrote Anzeige bedeutet dass der Rotationswinkel aus den Winkeln der einzelnen Messpunkte nicht den Anforderungen gen gt mindestens 60 Eine gelbe Anzeige bedeutet d...

Page 115: ...etektorabdeckungen auszurichten Bild 1a b Wenn die Laserstrahlen auf beiden Empf ngern zentriert sind ffnen Sie die Abdeckungen Auf dem Bildschirm werden nun die X Y Koordinaten und die Position f r b...

Page 116: ...en Funktionen in diesem Bildschirm Distanzscheiben Simulation Beobachten des berechneten Versatzes Live Ausrichtung durchf hren Live Ausrichtung pausieren weiterf hren Manuelle Winkeleingabe falls akt...

Page 117: ...e Ausrichtung benutzt werden kann Sonst ist dies f r die jeweilige Ebene nicht m glich Diese blinkende Fehlermeldung bedeutet dass die Position der Wellen unerwartet ver ndert wurde Die Live Ausrichtu...

Page 118: ...Ausrichtung ab nur dass hier die Sensoren nicht in eine vordefinierte Position gebracht werden m ssen Es ist jedoch empfehlenswert die Sensoren ca in einem Winkel von 45 zu positionieren 45 135 225 31...

Page 119: ...anzen ber die RPM Umdrehungen pro Minute festlegen Manuelle Eingabe von Toleranzen Wenn RPM Auswahl aktiviert ist RPM um einen Schritt erh hen Wenn Manuelle Eingabe aktiviert ist Parallelversatz Einga...

Page 120: ...r Stelle in einem Eingabefeld befindet dr cken Sie die Taste zweimal um ein negatives Vorzeichen einzugeben Speichern und verlassen 6 1 4 3 Distanzscheiben Simulation Um Distanzscheiben zu simulieren...

Page 121: ...Zu beachten in diesen Bildschirm Shortcuts in diesem Bildschirm Kontrollieren Sie nach der Ausrichtung das Resultat indem Sie eine weitere Messung vornehmen Neue Daten ermitteln Funktionen in diesem...

Page 122: ...zuf gen dr cken Sie Zu beachten in diesem Bildschirm Shortcuts in diesem Bildschirm Benutzen Sie die biaxial live Funktion nur bei stabilen Wellenpositionen da schon kleinste Drehungen zu Fehlern f hr...

Page 123: ...gabe von Ys und Ym Werten wenn aktiviert Manuelle Neigungseingabe Auswahl der Ma einheit mm Zoll Durch gesammelte Daten navigieren Messwerte l schen erg nzen ersetzen Von vorne beginnen alle Werte l s...

Page 124: ...ert kann bei Bedarf gel scht oder ersetzt werden Ist dieses Symbol nicht zu sehen hei t das dass der aktuelle Wert noch nicht gespeichert wurde Durch Dr cken von k nnen Sie den Wert speichern Das Fehl...

Page 125: ...et dass die Daten nicht gut aber akzeptabel sind Ein roter Punkt bedeutet dass die Daten schlecht sind Diese Messung muss gel scht oder wiederholt werden Wenn Sie eine geringe Anzahl von Messpunkten v...

Page 126: ...it dem Ausrichten zu beginnen 6 2 3 1 Einstellen des Parallelversatzes Dr cken Sie um den Parallelversatz einzustellen Zu beachten in diesem Bildschirm Shortcuts in diesem Bildschirm Drehen Sie nicht...

Page 127: ...ellen Auswahl der Ma einheit mm Zoll Eingabe von Toleranzen Flanschbolzen Korrekturwerte ansehen mit Live Update Ergebnisse der Ausrichtung speichern Ergebnisse der Ausrichtung laden Zur Flansch Bolze...

Page 128: ...ie laterale Position der bewegbaren Maschine 9 3 Ebene Live Ausrichtung Um die 9 3 Ebene Live Ausrichtung zu starten sollten sich die Sensoren in der 9 oder 3 Uhr Position befinden Wenn Sie die Wellen...

Page 129: ...n gebracht werden m ssen Es ist jedoch empfehlenswert die Sensoren ca in einem Winkel von 45 zu positionieren 45 135 225 315 um Messfehler zu vermeiden 6 2 4 1 Bolzen Korrekturwerte ansehen Um die Kor...

Page 130: ...anzen ber die RPM Umdrehungen pro Minute festlegen Manuelle Eingabe von Toleranzen Wenn RPM Auswahl aktiviert ist RPM um einen Schritt erh hen Wenn Manuelle Eingabe aktiviert ist Parallelversatz Einga...

Page 131: ...er horizontalen Ausrichtung oder berspringen Sie diesen Vorgang indem Sie dr cken und gehen Sie zum Sensor Ziel Bildschirm Wenn die Laserstrahlen ausgerichtet sind und Sie den Sensor Ziel Bildschirm v...

Page 132: ...rschiede zu diesen Kapiteln werden im Folgenden beschrieben Gelenkwellen Hauptmen Zu beachten in diesem Bildschirm Shortcuts in diesem Bildschirm Vor der Messung sollte eine Kippfu messung durchgef hr...

Page 133: ...cuts in diesem Bildschirm Strecke Sensor S Sensor M eingeben Strecke vorderer Maschinenfu hinterer Maschinenfu eingeben Zwischen den Eingabefeldern nach oben navigieren Zwischen den Eingabefeldern nac...

Page 134: ...leingabe aktivieren deaktivieren Manuelle Eingabe oder Benutzung der Sensordaten Manuelle Winkeleingabe oder Daten aus integriertem Neigungssensor Auswahl zwischen 2 oder 3 Nachkommastellen Auswahl zw...

Page 135: ...maschine festzulegen Um diese Funktion zu nutzen sollten Sie mit dem Ablauf der horizontalen Maschinenausrichtung Kapitel 6 1 vertraut sein Durchf hren einer Maschinenzug Ausrichtung Um das Programm z...

Page 136: ...len Kupplung bedeutet dass die Abmessungen korrekt eingegeben wurden und Daten korrekt ermittelt wurden Dr cken Sie oder um durch den kompletten Zug zu scrollen dr cken Sie um die Abmessungen f r die...

Page 137: ...nd immer f r die linke Welle bzw Maschine g ltig Heranzoomen Herauszoomen Aktuelle Maschine als Referenzmaschine festlegen Ergebnisse in Datei abspeichern siehe Kapitel 9 Umgang mit Datei Dialogfenste...

Page 138: ...n diesem Bildschirm Anzahl der Messpunkte Positionen eingeben Abmessungen eintragen Messung starten Messergebnisse betrachten verf gbar wenn alle ben tigten Messungen abgeschlossen sind Speichern Abst...

Page 139: ...u verlassen dr cken Sie Um das Spindel Programm zu verlassen dr cken Sie anschlie end erneut Um die Ergebnisse zu speichern dr cken Sie siehe Kapitel 9 Umgang mit Datei Dialogfenstern Etikettenpositio...

Page 140: ...zu erhalten sollten Sie die Ausrichtung sehr vorsichtig durchf hren mit Hilfe von Libellen Planen Sie die Messung indem Sie den Sender in der ersten Position 12 Uhr platzieren best tigen Sie die Posi...

Page 141: ...Bildschirm Anzahl der Messpunkte Positionen eingeben Punkte erstellen modifizieren betrachten Parameter ndern Abmessungen eintragen Messung starten Ergebnisse betrachten verf gbar wenn alle ben tigte...

Page 142: ...e end um den Abstand zum n chsten Punkt einzutragen Wiederholen Sie diesen Vorgang bis alle Abst nde eingetragen sind Um Parameter zu ndern dr cken Sie Es erscheint der Parameterbildschirm Zum Ein ode...

Page 143: ...tiviert Manuelle Eingabe des Empf ngerwerts H Manuelle Winkeleingabe ben tigt zur Positionsbest tigung Umschalten zwischen den Ma einheiten Kontextmen ffnen Messung durchf hren oder ersetzen Vorw rts...

Page 144: ...nzpunktnummer 2 ein Dr cken Sie nun zum Best tigen Um einen Referenzpunkt zu l schen geben Sie als Wert ein Best fit Modus In diesem Modus ist das Ergebnis die Differenz aus der berechneten geeignetes...

Page 145: ...alls aktiviert Zwischen Tabellen und Graphansicht umschalten Referenzpunkt definieren benutzen Sie um die Eingabe zu best tigen Referenzpunktmodus umschalten Speichern Messung wiederholen alle aktuell...

Page 146: ...BETRIEBSANLEITUNG 49 Ref points Modus Best fit Modus Rot bedeutet Toleranz berschreitung...

Page 147: ...ie die Punkte an denen der Empf nger positioniert werden soll Richten Sie den Laser in X und Y Richtung innerhalb von 0 5 mm aus und starten Sie das Ebenheits Programm Benutzen Sie den S oder M Sensor...

Page 148: ...den Auto Router Einstellungen zu gelangen dr cken Sie Dr cken Sie zum Speichern und Verlassen dieses Bildschirms Auto Router Der Auto Router kann deaktiviert oder in den zwei folgenden Modi konfigurie...

Page 149: ...mgekehrt Das Gitter wird mit gleichbleibenden Zeilen bzw Spaltenabst nden definiert Einzelne Abst nde k nnen sp ter aber noch unabh ngig voneinander ge ndert werden Dr cken Sie um zu speichern und zum...

Page 150: ...gen Zeile wird an der Unterseite eingef gt Ring als u erer Ring Zeile Ring zu der dem der ausgew hlte Punkt geh rt l schen Spalte Punkt einf gen Spalte wird auf der rechten Seite eingef gt Punkt im U...

Page 151: ...e Daten bereit sind bevor Sie die n chste Messung durchf hren Sanduhr Symbol darf nicht blinken Gew hlten Punkt l schen Funktionen in diesem Bildschirm Ergebnis betrachten Messung an gew hltem Punkt d...

Page 152: ...Achsen Wert Laserstrahl Positionsindikator Gew hlter Punkt Blinkendes Symbol Laserstrahl au erhalb des Ziels Gemessener Punkt Leerer Punkt Empf nger Y Achsen Wert Sensor Neigung Sensor Temperatur Pun...

Page 153: ...renzebenen Modi Es gibt drei Referenzebenen Modi zwischen denen Sie mit umschalten k nnen Keine Referenzebene No reference plane Das Ergebnis ist der unver nderte Empf ngerwert Laser Referenzebene Las...

Page 154: ...Ergebnis Modi Es gibt drei Ergebnis Modi zwischen denen Sie mit umschalten k nnen Original Werte werden als positive und negative Werte angezeigt All positive Werte werden relativ zum niedrigsten Wer...

Page 155: ...ert an Minimum Zeigt Minimalwert an Peak Peak Zeigt den Spitze Spitze Wert an Average Zeigt den Durchschnittswert an Std deviation Zeigt die Standardabweichung vom Durchschnittswert an Tolerance Zeigt...

Page 156: ...ogramm zu starten w hlen Sie Loch Mittelachse im Hauptmen unter dem Punkt Geometrie und dr cken Sie Es erscheint der Hauptbildschirm des Programms 7 2 1 Hauptbildschirm des Programms Ebenen konfigurie...

Page 157: ...onfiguration Geben Sie die Anzahl der Ebenen L cher ein indem Sie dr cken und den Wert im Eingabefeld eingeben der Wert sollte zwischen 3 und 300 liegen Sind die zu messenden Ebenen in gleichen Abst n...

Page 158: ...er verwenden m chten Zur Durchschnittswertbildung dr cken Sie geben Sie eine Probenanzahl ein und best tigen Sie mit Dr cken Sie zum Speichern und Verlassen des Parametermen s 7 2 2 Messungen durchf h...

Page 159: ...n Sie eine Weile Keine Verbindung zu den Sensoren Aktuelle Messpunktnummer Ein bedeutet keine Messung Detektorwert bedeutet keine Daten Empf ngerneigung in Grad bedeutet keine Daten Gespeicherte Messp...

Page 160: ...ebnis zu berechnen Speichern Sie so viele Messungen wie m glich bis zu 36 um ein m glichst genaues Ergebnis zu erhalten Der minimale Gesamtdrehwinkel Summe der einzelnen Drehungen zwischen den einzeln...

Page 161: ...ein Dr cken Sie zum Speichern Um die Referenzpunkte zu l schen geben Sie als Wert ein Best fit Modus Im diesem Modus ist das Ergebnis die Differenz aus der berechneten Best fit Referenzlinie und dem...

Page 162: ...te auf dem Bildschirm Um den Live Modus zu stoppen und das Ergebnis nach dem Bewegen zu erhalten dr cken Sie Stoppen Sie den Live Modus nicht w hrend die Messdaten nicht bereit sind Laserstrahl au erh...

Page 163: ...Neue Messung starten Funktionen in diesem Bildschirm Anzahl der Messpunkte Positionen eingeben Punkt erstellen modifizieren betrachten Teilst ck Splice erstellen modifizieren betrachten Parameter nder...

Page 164: ...Geradlinigkeitsmessung des ganzen Objektes korrekt durchf hren zu k nnen Wenn die Nutzl nge des Lasers l nger als das zu messende Objekt ist kann auf die Verwendung von Teilst cken Splices verzichtet...

Page 165: ...ter ndern wollen dr cken Sie um in den Parameterbildschirm zu gelangen Hier k nnen Sie die manuelle Dateneingabe mit Druck auf oder die manuelle Winkeleingabe mit Druck auf aktivieren deaktivieren Dur...

Page 166: ...erstrahls auf dem Empf nger mit Hilfe der Justierschrauben am Transmitter Der Laserstrahl sollte wieder mittig auf das Ziel auf dem Empf nger treffen Bewegen Sie jetzt den Empf nger zum ersten Messpun...

Page 167: ...die Differenz zwischen der kalkulierten Referenzlinie und dem Empf ngerwert Um Referenzpunkte zu definieren dr cken Sie und geben Sie dann Referenzpunktnummer 1 und Referenzpunktnummer 2 ein Dr cken S...

Page 168: ...um zum Hauptbildschirm zur ckzukehren Anzahl der berechneten Punkte einschlie lich berlappungspunkte Distanz berlappungspunkte Punktnummer und Teilst cknummer Teilst cknummer wird nur bei Verwendung...

Page 169: ...e Ausrichtung f r das zweite Teilst ck durch Beachten Sie Folgendes Punkt 1 auf dem zweiten Teilst ck hat dieselbe physische Position auf dem Objekt wie Punkt 4 auf dem ersten Teilst ck Punkt 2 auf de...

Page 170: ...dus f r die neu gew hlte Ebene zu starten Das Ausrichten eines Punktes kann sich auf andere Punkte auswirken Wiederholen Sie also die Messungen nach dem Benutzen des Live Modus gehen Sie zum Ergebnis...

Page 171: ...Bildschirm Shortcuts in diesem Bildschirm Die ben tigten Abmessungen sollten korrekt eingetragen sein sie k nnen sp ter bei Bedarf noch ge ndert werden Neue Messung beginnen bzw Messung wiederholen a...

Page 172: ...um 90 in Richtung der zweiten Fl che F hren Sie nun Messungen f r die Punkte 3 und 4 durch Der RL 20 Lasersender darf nicht bewegt werden nachdem die Messung begonnen wurde Seien Sie vorsichtig bei de...

Page 173: ...ezeigt Systemeinstellungen 8 Funktionen in diesem Bildschirm Shortcuts in diesem Bildschirm Datum und Uhrzeit einstellen Automatische Abschaltung konfigurieren Programmlizenzen ansehen einrichten Eins...

Page 174: ...en den Feldern nach rechts bewegen Aktuellen Wert erh hen Aktuellen Wert verringern Zwischen den Feldern nach links bewegen zyklisch Datum und Uhrzeiteinstellungen verlassen Fenster schlie en Sensor S...

Page 175: ...dschirm Einstellen der Abschaltzeit in Sekunden Hinweis 1 Um die automatische Abschaltung zu deaktivieren setzen Sie diese auf null oder lassen Sie das Eingabefeld leer Hinweis 2 Wenn Werte unter 30 S...

Page 176: ...dieser Ihnen die Lizenzdatei zusendet kopieren Sie diese in den My documents Ordner auf dem Ger t oder auf die SD Karte und setzen Sie diese ein Um die Datei zu laden dr cken Sie und ein Ladedialog er...

Page 177: ...lle ausw hlen Wenn Bluetooth aktiviert ist Einen Sensor ber Bluetooth verwenden Beide Sensoren ber Bluetooth verwenden Klasse des Bluetooth Slave Ger tes ndern so lassen COD ver ndern Sie diese nicht...

Page 178: ...en tigt um auf das Ger t zugreifen zu k nnen F hren Sie keine Lade oder Speichervorg nge auf dem Ger t durch w hrend auf das Ger t per USB im Massenspeicher Modus zugegriffen wird Funktionen in diesem...

Page 179: ...Der My Documents Ordner intern immer vorhanden Der Storage Card Ordner externe SD Karte nur vorhanden wenn eine SD Karte eingelegt ist Genereller Aufbau des Datei Dialogfensters Ordner und Dateiliste...

Page 180: ...d Sie sich in einem Unterordner befinden bewegen Sie sich eine Stufe in der Ordnerhierarchie nach oben Wenn die Ordner und Dateiliste ausgew hlt ist L schen des Ordners der Datei Vorsicht Wenn die Ord...

Page 181: ...Dateien l schen Neue Ordner erstellen Wenn die Ordner und Dateiliste ausgew hlt ist Durch die Liste navigieren Wenn das Speichermedium Auswahlfeld ausgew hlt ist Auswahl zwischen SD Karde Storage Card...

Page 182: ...tufe nach oben bewegen Wenn die Ordner und Dateiliste ausgew hlt ist Datei oder Ordner l schen Wenn Ordner und Dateiliste ausgew hlt ist neuen Ordner erstellen Zwischen der Ordner und Dateiliste dem S...

Page 183: ...Winkelversatz Parallelversatz Winkelversatz Bis 1000 0 08 0 07 0 12 0 10 Bis 2000 0 06 0 05 0 10 0 08 Bis 3000 0 04 0 04 0 07 0 07 Bis 4000 0 03 0 03 0 05 0 05 Mehr als 4000 0 02 0 02 0 04 0 04 Datein...

Page 184: ...V PCE Deutschland GmbH Im Langel 4 59872 Meschede Zur Umsetzung der ElektroG R cknahme und Entsorgung von Elektro und Elektronikaltger ten nehmen wir unsere Ger te zur ck Sie werden entweder bei uns w...

Reviews: