Manual
64
8.1.10 View and save results
For a better understanding, the measurement results are displayed as a grid, where the relative position
of the individual items is graphically displayed. Each point is displayed as a coloured circle or as a
colouered triangle (triangle = reference point) and is equipped with
„+“, „-„ or 0.
„+“ indicates above and „-„ indicates beneath the reference plane.
The
blue colour
indicates “excellent”(tolerance <25%)
The
green colour
indicates ”good” (tolerance < 50%)
The
yellow colour
indicates ”warning” (tolerance <100%)
The
red colour
indicates “bad” (tolerance < 50%)
The headline of the screen shows the coordinates and the measurement value of the selected point. The
value depends on the selected mode.
8.1.11 Reference modes
There are three reference modes, you can select between by pressing
.
8.1.11.1 No reference plane
The result is an unchanged receiver value
8.1.11.2 Laser Plane
If no reference points are defined, the result is an unchanged receiver value, if three reference points are
defined, the result is the difference between the calculated three-point-reference plane and the receiver
value.
8.1.11.3 Best-Fit Plane
The result is the difference between the calculated Best-Fit-Plane and the receiver value.
Coordinates of
the point
[line:column]
Measurement
result of the
point
Data for the point are
available (was not
skipped)
X-axis position
of the point
Reference point
(if selected)
View statistics
change
Edit point
Define/reset
reference point
Change value
mode
Y-axis position
of the point
Displacement
of the point
Tolerance
value (here
0,74)
Change
reference plane
save
Back to data
acquisition