Communication Failures–––––––––––––––––––––––––––––––––––––
Errors 410 to 413 are usually caused by a hardware failure, by
an incorrect SETUP option or by the host ignoring flow control
(XON/OFF, CTS/RTS or DTR).
n
The valid communication settings are shown below.
Baud rate
1200, 2400, 4800, 9600, 19200
Word length
7 or 8
Stop bits
1 or 2
Parity
Odd, Even, None
Flow control
None, XON/XOFF, DTR, CTS
Reset
Yes or No
Error
Code
Description/Action
410
Parity on the printer does not match the parity on
the host. Check the parity setting under SETUP
options.
411
Framing error. The printer cannot communicate with
the host. Make sure the host is turned on,
communication cables are connected correctly,
communication settings are correct, and
communications are active. Check the baud rate,
word length, and stop bits to make sure they match
those at the host. Do not toggle between
MS-Windows and MS-DOS, while using the COPY
command, or you will receive a framing error. (Exit
MS-Windows
before
using the COPY command.)
Re-transmit the data.
MPCLII Packet Reference Manual
9-12
Summary of Contents for Monarch 1460
Page 14: ...MPCLII Packet ReferenceManual 1 6 ...
Page 76: ...MPCLII Packet ReferenceManual 4 24 ...
Page 94: ...MPCLII Packet ReferenceManual 5 18 ...
Page 116: ...MPCLII Packet ReferenceManual 7 14 ...
Page 154: ...MPCLII Packet ReferenceManual 10 8 ...
Page 162: ...MPCLII Packet ReferenceManual A 8 ...
Page 166: ...MPCLII Packet ReferenceManual A 12 ...
Page 168: ...Bold Font OCRA like Font Standard Font Reduced Font MPCLII Packet ReferenceManual B 2 ...
Page 169: ...CG Triumvirate Bold Font CG Triumvirate Font Appendix B Fonts B 3 ...
Page 183: ...Code Page 437 Appendix C Symbol Sets CodePages C 7 ...
Page 184: ...Code Page 850 MPCLII Packet ReferenceManual C 8 ...
Page 188: ...MPCLII Packet ReferenceManual C 12 ...
Page 216: ......